Here the default GPI settings can be adjusted. For GPI only, the TCP commands are not used.

For an Axia node the GPI or GPO can be selected with the corresponding pin where the color RED 
will be activated. GPI1 – 8, GPO1 – 8 and Pin 1-5. 

For an Axia QOR the name of the fader channel needs to be entered in the TCP 1 field. For example 
Mic-DJ or Mic 1. The name entered here has to correspond exactly to the name used in the QOR 
and is case sensitive.
On change of a show profile on the Axia desk from example fader 1 to fader 3 the MOS-UNO-IP 
will follow the change.
On first installation or reboot of the MOS-UNO-IP a show profile has to be loaded to let the MOS-
UNO-IP know the corresponding fader channel. 
GPIO, Pin and TCP off settings are not used when the QOR has been selected.

On choosing listen to server the MOS-UNO-IP will only listen on TCP port93 to commands 
directly send to the IP address of the MOS-UNO-IP. To activate or deactivate the red light, the send 
command has to exactly match the commands in TCP on and TCP off. These commands are case 
sensitive. 

The MOS-UNO-IP uses standard ASCII charracters for the TCP commands. To test a command a 
simple freeware program like packet sender can be used.

On the use of DHD global logics the name of TCP on and off will change After saving settings. 

GPI settings

Содержание MOS - UNO - IP

Страница 1: ... 0 9 396 76 40 INFO AEROAUDIO EU Status indication white or red Mika microphone input Microphone output Ethernet network connection SUB D 9 GPI input Power supply 12 till 24 volt DC polarity is not important Power consumption at 12 volts 100mA at 24 volts 70mA ...

Страница 2: ... IP and wait for 5 seconds during boot the status LED will blink fast in red After the reset boot the satus LED will turn white and facory default settings are restored The MOS UNO IP can be reached at 192 168 0 101 again GPI schematic Pin Function Signal 1 GPI voltage control 5 till 15 volt DC 2 GPI close contact to GND Contact to pin 7 8 of 9 3 4 5 RESET settings Contact to pin 7 8 of 9 6 GND GP...

Страница 3: ...er the IP address in your browser and the MOS UNO IP will display the following settings page Mode Discription selected Current settings SUB D GPI only Triggers only on SUB D GPI Connect to device Connects to an Axia node or QOR Listen to server Triggers on TCP commands Connect to device connects directly to an Axia node or QOR Listen to server listens to TCP commands send from an external TCP ser...

Страница 4: ...ts on the QOR to trigger the MOS UNO IP select Node as device On using the Axia livewire software driver the Node needs to be selected as device DHD global logics Listens to DHD global logics Enter the DHD Toolbox project ID in the field of TCP command 1 Enter the used global logic number 1 200 in the field of TCP command 2 See GPI settings for details The webpage of the MOS UNO IP shows the conne...

Страница 5: ... to fader 3 the MOS UNO IP will follow the change On first installation or reboot of the MOS UNO IP a show profile has to be loaded to let the MOS UNO IP know the corresponding fader channel GPIO Pin and TCP off settings are not used when the QOR has been selected On choosing listen to server the MOS UNO IP will only listen on TCP port93 to commands directly send to the IP address of the MOS UNO I...

Страница 6: ...ngs Here the IP address with the corresponding subnet mask can be set The MAC address is unique for each device and can not be changed The firmware shows the currently running firmware version of the device Save settings After setting all system parameters these settings have to be saved To save all settings click save and reboot The MOS UNO IP will store all settings and reboot After approximatel...

Страница 7: ...MOS UNO IP MANUAL Dimensions STEENWEG 148C 9810 NAZARETH BELGIUM T 32 0 9 396 76 40 INFO AEROAUDIO EU Dimensions 140 81 9 41 6 mm Weight 0 35 Kg ...

Страница 8: ...ower supply Do not use the unit if the power cord is frayed or broken Turn off and disconnect the devices from the power supply before making any connections Do not use the unit near heaters heating vents radiators or other devices that produce heat Do not use the unit on a surface or in an environment that may interfere with the normal flow of air around the unit If the unit is used in an extreme...

Отзывы: