background image

National Warranty Hotline|1300 116 305

 

Monday to Friday 9am to 5pm AEST

10

INSTALLING FAN - WITH LIGHT CONTINUED

7

8

11

10

12

13

9

Содержание Storm 52

Страница 1: ...UCTED TO DO SO National Warranty Number 1300 116 305 Monday to Friday 9am to 5pm AEST g NOTE THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS Australian Edition Version 2 1 April 2020 Installation User Manual PLEASE NOTE THE REMOTE CONTROL COMES PRE PROGRAMMED TO THE FAN REPROGRAMMING IS ONLY REQURED WHEN REPLACING THE REMOTE CONTROL...

Страница 2: ...d off at the main power box before commencing work Disconnect power by removing fuse or turning off circuit breaker before installing the fan Ensure all spliced connections are adequately insulated 10 Warning Do not allow the rotating fan blades to come into contact with any object this can cause serious injury or death 11 Damage caused by incorrect installation Force majeure lightning electrical ...

Страница 3: ...between two beams After the fan is completely installed check to make sure that all connections are secure to prevent the fan from falling and or causing damage or injury To reduce the risk of personal injury do not bend or damage the motor or Fan Assembly when handling or during installation Please ensure special care is taken when assembling the fan Each screw must be sufficiently tightened TABL...

Страница 4: ...le damage please only remove the parts when required for installation To avoid possible electrical shock be sure electricity is turned off at the main fuse box before assembling and wiring the fan WARNING Hanger Bracket Bracket Mounting Screw Hanger Ball Screw Ceiling Canopy Receiver Downrod Downrod Joint Cover Fan Motor Blade Blade Screw Bottom Cover Hanger Ball Part Quantity Part Quantity Hanger...

Страница 5: ...r installation To avoid possible electrical shock be sure electricity is turned off at the main fuse box before assembling and wiring the fan WARNING Hanger Bracket Receiver Bracket Mounting Screw Hanger Bracket Ceiling Canopy Downrod Downrod Joint Cover Fan Motor LED Lamp Blade Blade Screw Lamp Cover Lamp Panel Cover Part Quantity Part Quantity Hanger Bracket 1 Fan Motor 1 Bracket Mounting Screws...

Страница 6: ...urning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING EXTENSION ROD OPTIONAL ACCESSORY In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object PLEASE NOTE The with light fan includes a se...

Страница 7: ...tline 1300 116 305 Monday to Friday 9am to 5pm AEST 6 INSTALLING EXTENSION ROD OPTIONAL ACCESSORY CONTINUED WITHOUT LIGHT LOOM FAN LOOM A WITH LIGHT LOOM FAN LOOM B INSTALLING HANGER BRACKET ENSURE CAN TAKE 10KG LOAD 1 2 3 ...

Страница 8: ...wer box or disconnect power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITHOUT LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 1 3 2 4 5 ...

Страница 9: ... LIGHT CONTINUED 7 8 9 10 11 DANGER Before commencing installation turn off electricity supply at the main power box or disconnect power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations ...

Страница 10: ...power box or disconnect power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITH LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 1 2 3 4 5 6...

Страница 11: ...National Warranty Hotline 1300 116 305 Monday to Friday 9am to 5pm AEST 10 INSTALLING FAN WITH LIGHT CONTINUED 7 8 11 10 12 13 9 ...

Страница 12: ... same remote can be control multiple fans To remove a second remote see page 15 Removing a second remote programmed to a fan CHANGE LED COLOUR TEMPERATURE WITHLIGHT VERSION ONLY The light kit on the fan has three different colour temperature options 3000K 4000K 6000K To change the colour temperature using the remote control 1 Start with the light off and press the LIGHT ON OFF button three times w...

Страница 13: ...9am to 5pm AEST 12 REPLACING THE LED LIGHT PANEL IF REQUIRED PLEASE NOTE Should the light still not be functioning correctly once a new panel is installed a replacement reciver will also be required please contact customer service on 1300 116 305 1 2 3 4 5 6 ...

Страница 14: ...down the centre of the fan producing a cooling breeze The direction the fan will spin in FORWARD Summer when viewed from underneath will be anticlockwise REVERSE Winter Mode In REVERSE Winter mode your ceiling fan will spin the opposite direction Air is drawn up the centre of the fan and pushed along the ceiling to circulate down to the living areas The REVERSE Winter mode can also be for air circ...

Страница 15: ... chlorides this will increase maintenance requirements Even indoors in coastal areas the influx of warm sea air can accelerate the surface corrosion of metal parts This can still happen many kilometres from the sea When humidity is high and temperature drops moisture condenses on metal surfaces including ceiling fans The layer of moisture can be almost microscopic but it will affect the surface by...

Страница 16: ...ket is tight against the ceiling and the ceiling and ceiling structure is not moving Countersunk screws have been used Countersunk screws will make the fan wobble and either now or later allow the bracket to move Replace Countersunk screws with screws that have been supplied in box Fan is noisy Loose Screws or Parts Check all screws and parts are secured firmly be careful to never over tighten the...

Страница 17: ... the original purchase receipt or bill of sale along with a proof of installation by a Licensed Electrician to make a warranty claim No claim will be accepted without these documents being provided Please contact AeroDC via the warranty hotline web or email Please note carefully If the product is found to be free of defects or the product is not functioning properly as a result of faulty installat...

Страница 18: ...contrary claims for damage to furniture carpet walls ceilings foundations or any other consequential loss either directly or indirectly resulting from a faulty ceiling fan 7 Signals sent through the mains power supply by the electricity supplier for off peak hot water and other signals including those for street lights and such These signals may cause an intermittent humming in the ceiling fan It ...

Страница 19: ...er Wall controllers must only be types approved for use by AeroDC 2 The fan fan light assembly and bracket are earthed 3 Fan fan light and remote control receiver are run from the same final circuit via an isolation switch 4 Mounting bracket must be firmly secured to a solid structure such as a concrete ceiling steel structure or timber framing If additional bracing is added it must be firmly secu...

Страница 20: ...IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS 19 EM Imports Pty Ltd 10 Overlord Place Acacia Ridge Queensland Australia 4110 Warranty Support AeroDC Ph 1300 116 305 support aerodc com au National Warranty Hotline 1300 116 305 Monday to Friday 9am to 5pm AEST Distributed by ...

Отзывы: