background image

 

© Copyright Aero-Spa®, LLC 2021 REV H

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
Do not modify the plug provided; if it will not fit the outlet, have the 
proper outlet installed by a qualified electrician. This product is for use 
on a nominal 120-volt circuit. No adapter should be used with this 
product. This product has an automatic thermal limiter, which shuts 
off the entire product when an elevated temperature condition exists.  
When the product cools it will automatically restart. Only if required, 
obtain a UL outdoor rated extension cord. Never locate the Aero-Spa 
generator 

closer than 10’ from the hot tub. In the event of a power 

outage, the GFCI device will need to be reset manually. 
 
Occasionally GFCI breakers will experience nuisance tripping.  This 
will shut off the power to the equipment. If this occurs, press the 
“reset” button. If pressing the “reset” button does not start the 
equipment, unplug the cycle timer 

and press the “reset” button again. 

If the “reset” button does not “hold in”, replace the GFCI breaker.  If 
the button does “hold in”, plug the generator power cord into the GFCI 
breaker and circumvent the cycle timer.  Press t

he “reset” button 

again. 

If the “reset” button does not “hold in” replace the GFCI 

breaker. 

If the “reset” button does “hold in” contact Aero-Spa™.  

 

Do not operate this equipment without a GFCI breaker installed. 

 
 
 
 
 

 

Figure 4: GFCI Outlet 

DANGER: Improper installation of the grounding 

plug can result in a risk of electric shock.

 

Содержание AP 1000

Страница 1: ...Installation Guide For additional assistance please contact us at Technical Support 877 226 8111 OR info aero spa net...

Страница 2: ...e not intended to treat infections Never allow use of hot tub spa if you are unable to verify the condition of open sores wounds lesions cuts sores abrasions boil etc or infections of any type exist T...

Страница 3: ...nstallation guide Do not operate Aero Spa unit unless the electrical source is protected by a Ground Fault Circuit Interrupt GFCI device Do not use the Aero Spa unit for applications other than those...

Страница 4: ...red diffuser as they are fragile Identify the equipment components Ozone Generator Cycle Timer Ozone Tube and Sintered Diffuser Figure 1 Please note that your product may vary from photos in this inst...

Страница 5: ...not closer than 10 Do not extend or shorten the ozone tube If the tube is too long coil the excess tube in an 8 diameter coil Do not splice or modify the air line setup an improperly sized ozone tube...

Страница 6: ...nt hum from the generator and a steady bubble stream will be emitted from the diffuser Grounding Instructions This product must be grounded In the event of an electrical short circuit grounding reduce...

Страница 7: ...the GFCI device will need to be reset manually Occasionally GFCI breakers will experience nuisance tripping This will shut off the power to the equipment If this occurs press the reset button If pres...

Страница 8: ...tion of users To put this into perspective to obtain a 1 PPM ratio in a 500 gallon hot tub you would need to add about 0 63 OZ 1 25 tablespoons of regular household bleach 6 sodium hypochlorite If you...

Страница 9: ...ct Aero Spa LLC Strong ozone odor near Aero Spa generator 1 Verify ozone tube is not broken 2 Verify ozone tube is not pinched or disconnected 3 Unplug unit and call Aero Spa LLC Strong ozone odor in...

Страница 10: ...e 1 Increase hot tub circulation pump cycle time Synchronize circulation pump and Aero Spa run time Water is normally clear but turns cloudy during or just after use 1 Increase the cycle run time by 2...

Страница 11: ...sin 53029 visit our website at www aero spa net or e mail us at info aero spa net If Buyer is making a refund claim please provide the reason for seeking the refund MANUFACTURERS LIMITED WARRANTY DISC...

Страница 12: ...any other loss These limitations do not apply however to damages related to personal injury SOME STATES DO NOT ALLOW LIMITATION ON INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITIATIONS MAY NOT...