OPERATION

Use an on/off switch to operate this fan. See “CONNECT ELECTRICAL WIRING” for details.

1. Do not use in a cooking area.                                          
2. Two ways to connect ductwork to a factory-shipped unit.

ASSEMBLY INSTRUCTIONS

ROOF CAP*

(with built-in

damper)

ROUND

DUCT*

WALL CAP*
(with built-in
damper)

*

 Purchase

separately

POWER

CABLE*

INSULATION*

(Place around and

over Fan Housing.)

Seal gaps

around

Housing.

FAN

HOUSING

ROUND 

ELBOW(S) *

Seal duct

joints with

tape.

Keep duct
runs short

PLAN THE INSTALLATION

1. Sliding hanger bars have been provided, which allow the housing 

to be positioned accurately anywhere between the framing. The 
bars span up to 24 in. and can be used on all types of framing: 
I-joist, standard joist, and truss construction. Slide hanger bars onto 
housing and adjust as needed to fit between framing.

Hanger Bar

HUMIDITY SENSOR (AP200DH-S) 

SENSOR OPERATION
The humidity control and fan can be operated separately. Use a 1- or 2- function wall control. Do not use a dimmer switch to operate 
the humidity control. See “Connect Wiring” for details.

 

The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid increases in humidity or (b) humidity above a 
user-adjustable setpoint (30%-80% relative humidity). The humidity sensor may occasionally turn the fan ON when environmental 
conditions change. If the fan continuously responds to changing environmental conditions, “H” (means “humidity”) adjustment may be 
required. This figure is factory-set for about 80% (Ambient temperature of 25

).

SENSITIVITY ADJUSTMENT

The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness control, 
the “H” may need to be increased toward maximum “+”. If the control is responding too often to changing environmental conditions, 
movement toward less “-” “H” may be required.To adjust the “H”:
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked “H”.
3. Carefully rotate the “H” adjustment toward “+” or “-”.
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.
5. Repeat above steps if necessary.
When the temperature changes, humidity sensor values will have deviation.

TIMER ADJUSTMENT

The humidity sensing fan has a “T” (means timer) that can be adjusted from 5 to 60 minutes (factory-set at about 20 minutes).This “T” 
controls the length of time that the fan remains ON after the sensor has stopped sensing a rise in humidity and the humidity level is 
below the user-adjustable set-point. 
To adjust the “T”:
1. Disconnect power at service entrance;
2. Through the grille, locate the slot marked “T”;
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes).
4. Check operation by turning on a humidity source until the fan turns on.
5. Turn humidity source off and time the unit.
6. Repeat above steps if necessary.

2

Содержание AP200D-S

Страница 1: ...e Protection Associa tion NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities f Ducted fans must always be vented to the outdoors g Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit In...

Страница 2: ... fan continuously responds to changing environmental conditions H means humidity adjustment may be required This figure is factory set for about 80 Ambient temperature of 25 SENSITIVITY ADJUSTMENT The H has been factory set for most shower applications However if the fan is in a tub area or is being used for dampness control the H may need to be increased toward maximum If the control is respondin...

Страница 3: ... Refer to the wiring diagram and connect the wires as shown ASSEMBLY INSTRUCTIONS 3 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not included Using tape not included secure all the ductwork connections so that they are air tight The ducting from this fan to the outside of building has a strong effect on the a...

Страница 4: ...e in normal household use for a period of 72 months THIS WARRANTY DOES NOT COVER Damages from improper installation Damages from shipping Damages from misuse abuse accident alteration lack of proper care and maintenance Damages from service by persons other than a licensed electrician Does not cover any labor or transportation charges related to the repair of this product This warranty does not ex...

Страница 5: ...tilateurs doivent toujours être évacués vers l extérieur g Peut être utilisé au dessus d une baignoire ou d une douche lorsqu elle est branchée à un DDFT disjoncteur détecteur de fuite à la terre circuit de dérivation protégé installation de plafond uniquement h Cet appareil doit être mis à la terre i Ne doit pas être utilisé dans la cuisine j Pour réduire les risques d incendie et pour évacuer l ...

Страница 6: ...e ambiant de 25 L AJUSTEMENT POUR LE SENSITIVITÉ Le H humidité senseur et fixé par l usine pour le plupart de douche bain applications typiques Si le ventilateur est dans une douche ou une baignoire ou être utilisé pour contrôler l humidité le H humidité senseur doit être augmenter à maximum Si le senseur d humid ité répond plus souvent aux conditions dans l environnement qui changent il faut rédu...

Страница 7: ...ement des raccords homologués par UL pour relier le circuit électrique de votre maison à la plaque de câblage Branchez les fils comme illustré ci dessous BLK BLK VENT WHT WHT GRD GRD BOÎTIER DE COMMUTATEUR UNITÉ ENTRÉE COMMUTATEUR MISE À TERRE GRD NOIR BLK BLANC WHT PANNEAU DE CONNEXION BOÎTIER DE COMMUTATEUR UNITÉ ALIMENTATION 120V CA RÉCEPTACLE COMMUTATEUR INSTALLATION DE LA GRILLE NOIR BLK NOIR...

Страница 8: ...eux dans un usage domestique normal pour une période de 72 mois CETTE GARANTIE NE COUVRE PAS Les dommages causés par une mauvaise installation Les dommages causés par l expédition Les dommages causés par un usage abusif accident modification manque de soins appropriés et l entretien Les dommages causés par un service par des personnes autres qu un électricien agréé Ne couvre pas les frais de main ...

Страница 9: ...tadounidense de Ingenieros de Calefacción Refrigeración y Aire Acondi cionado ASHRAE por sus siglas en inglés y los códigos locales vigentes e Al cortar o taladrar en paredes o techos no dañe el cableado eléctrico y otros servicios ocultos f Los ventiladores de conductos siempre deben orientarse hacia el exterior g Aceptable para su uso sobre una bañera o ducha cuando se conecta a un circuito deri...

Страница 10: ... fábrica en aproximadamente un 80 temperatura ambiente de 25 C AJUSTE DE SENSIBILIDAD La H se ha configurado de fábrica para la mayoría de las aplicaciones en duchas Sin embargo si el ventilador está en el área de la bañera o se utiliza para controlar la humedad puede ser necesario aumentar la H hacia el máximo Si el control actúa con demasiada frecuencia a las condiciones ambientales cambiantes p...

Страница 11: ...REDONDO Conecte el conducto redondo no incluido al conector de la compuerta conducto y lleve el conduc to hasta la cubierta de techo o pared no incluida Usando cinta no incluida asegure todas las conexiones de los conductos para que sean herméticas El conducto de este ventilador al exterior del edificio tiene un gran efecto en el flujo de aire el ruido y el uso de energía del ventilador Utilice la...

Страница 12: ...efectuosa en el uso doméstico normal por un período de 72 meses ESTA GARANTÍA NO CUBRE Daños por instalación incorrecta Daños por el transporte Daños por mal uso abuso accidente alteración falta de cuidado y mantenimiento adecuados Daños causados por la asistencia de personas que no sean electricistas autorizados No cubre los gastos de mano de obra o transporte relacionados con la reparación de es...

Отзывы: