1.6 Accessories available
1.5 HRS - HRS W range unit technical data
(1)
Values referring to the nominal air flow rate including recovery unit and filters
(2) Noise pressure level: values referring to 1.5 metres from machine intake in free field. The operational noise level differs from the values indicated according to the functioning conditions, the reflex
noise and peripheral noise
(3)
Input power at the electric mains.
(4) Can be adjusted electronically with WM regulator
MODELLO /
MODEL
HRS
030
060
090
160
190
230
300
390
Portata aria nominale /
Nominal air flow
m³/h
300
620
920
1580
1850
2250
2950
3920
Pressione statica utile /
External static pressure
(1)
Pa
45
55
65
70
77
80
100
100
Assorbimento max. totale macchina /
Total max absorbed current
A
0,75
1,8
2,2
4,4
4,8
5,2
8,3
5
Pressione sonora /
Sound pressure level
(2)
db (A)
43
51
50
53
52
51
54
56
VENTILATORI /
FANS
030
060
090
160
190
230
300
390
Potenza disponibile all'asse /
Power input
W
92 x 2
(3)
90 x 2 147 x 2 350 x 2 350 x 2 350 x 2 550 x 2 750 x 2
Poli /
Poles
n°
4
Numero velocità /
Speed number
n°
1
(4)
3
(5)
1
(6)
Grado di protezione /
Enclosure protection
IP
44
55
44
55
Classe di isolamento /
Insulation class
F
Alimentazione elettrica /
Electrical supply
V/ph/Hz
230/1/50
400/3/50
Heat Recovery Units Installation, Use and Maintenance Manual
page 8
It is possible to intake or expel the air frontally and
laterally by simply changing the position of the
panels, as illustrated at the side.
This can simplify the realisation of the air ducts
greatly, bringing an effective saving to installation
times.
Accessories compatibility
HRS 090
HRS 160
HRS 190
HRS 230
HRS 300
HRS 390
HRS 030
HRS 060
HRS 090W
HRS 160W
HRS 190W
HRS 230W
HRS 300W
HRS 390W
HRS090CS
✔
HRS160CS
✔
HRS190CS
✔
HRS230CS
✔
HRS300CS
✔
HRS390CS
✔
HRS090ED
✔
HRS160ED
✔
HRS190ED
✔
HRS230ED
✔
✔
✔
HRS090S
✔
HRS160S
✔
✔
HRS230S
✔
✔
✔
HRS030SC
✔
HRS060SC
✔
HRS01AT
*
✔
✔
✔
✔
✔
✔
PX
✔
✔
✔
✔
✔
PX2
✔
✔
✔
✔
✔
*
Accessory installed in the factory,
compatible only with HRS W version
, to be requested when placing the order.
•
HRS_CS:
Section of water cooling/heating (with
stainless steel condensate drip tray).
• HRS_ED:
Regulation shutter.
• HRS_S:
N° 4 circular connection kits for direct
connection of the unit to the circular conduits.
- HRS090S (ø 315 mm)
- HRS160S (ø 355 mm)
- HRS230S (ø 400 mm)
• HRS_SC:
Electronic speed regulator.Anti-freeze
thermostat, allows to control that the temperatu-
re does not fall below a pre-established value. .
Accessory installed in the factory, to be
requested when placing the order for the
HRS W version.
• PX:
Control panel with switch-over.
Wall installation. (from size 090 to 300)
• PX2:
Control panel with switch-over. Wall instal-
lation (from size 090 to 300)
Содержание HRS 030
Страница 1: ...HEAT RECOVERY UNIT Installation Use and Maintenance Manual HRS HRS W 4530600_00 dated 0904 ...
Страница 26: ...Heat Recovery Units Installation Use and Maintenance Manual page 29 ...
Страница 27: ...Heat Recovery Units Installation Use and Maintenance Manual page 30 ...
Страница 28: ...Heat Recovery Units Installation Use and Maintenance Manual page 31 ...
Страница 29: ......