Clock timer
Start timer: 00:00
End timer: 00:00
Click on the “Period” label to open the page with the timer start and end time labels;
set by first of all clicking on the label of the time you want to set, then sliding your
fingertip over the time values until you select those required. Lastly, press the top
right button to save the data entered.
Click on the labels for parameters with numeric values to be inserted to display a
numeric keypad (with an indication of the range of permitted values) which you can
use to enter the required values:
Clock timer
Clock timer: Off
Mode: Heat
Period: 00:00~00:00
T water tank: 50°C
WOT Heat: 45°C
00 00
01 01
02 02
23 59
22 58
Min: 20 Max: 60
X
0
1
2
3
4
5
6
7
8
0
-
9
OK
Clock timer
Clock timer: Off
Mode: Heat
Period: 00:00~00:00
T water tank: 50°C
WOT Heat: 45°C
Note:
1.
If the requested mode is “Hot water”, the “WOT-Cool” or “WOT-heat“ parameter
will not be displayed;
2.
Every time you press on the label, the value will change. Once you have select-
ed the required value, press the icon to save and implement the setting;
3.
If the compatible Aermec accessory tank for this model (refer to the installation
manual for more information) is not installed and correctly set, the references
to hot water production will not be available;
4.
If the weekly timer and the standard timer are set at the same time, the weekly
timer takes priority;
5.
The timer start must always be prior to the timer end, otherwise the period
will not be valid;
6.
The timer for hot water production will only be available if the operating mode
envisages hot water production;
7.
The timer function will only work once. If you want to use it again, you must
re-set it;
8.
The timer is deactivated if the unit is manually switched on before the timer
start time;
9.
If the relative function is activated (paragraph "8.3 Activating/deactivating the
memory (On/off memory) p. 25"), the value of this parameter will be stored
in the memory and automatically reset after any possible voltage failure;
10.
The default value for this function is “Off”.
4.12 SETTING PROGRAMMED SETTING CHANGES ON
SYSTEM WATER DELIVERY (TEMP. TIMER)
00 00
01 01
02 02
23 59
22 58
Temp. timer
Temp. timer: Off
Period 1: 00:00
WT heat 1: 45°C
Period 2: 00:00
WT heat 2: 45°C
After accessing the “Temp. timer” function, you can set programmed variations of
the water delivery set-point (this set-point will depend on the currently active oper-
ating mode). The function can be activated or deactivated by clicking on the “Temp.
timer” label; click on the “Period 1” label to specify the time at which the water deliv-
ery set-point is to be changed, setting it to the value specified in the “WOT-heat 1”
parameter (which when clicked will display a numeric keypad to change its value).
Set “Period 2” with related “WOT-heat 2” in the same way.
Click on the labels for the delivery temperature parameters to display a numeric
keypad (with an indication of the range of permitted values) which you can use to
enter the required values:
Temp. timer
Temp. timer: Off
Period 1: 00:00
WT heat 1: 45°C
Period 2: 00:00
WT heat 2: 45°C
Min: 25 Max: 60
X
0
1
2
3
4
5
6
7
8
0
-
9
OK
Temp. timer
Temp. timer: Off
Period 1: 00:00
WT heat 1: 45°C
Period 2: 00:00
WT heat 2: 45°C
Note:
1.
Press the icon to save and implement the setting;
2.
This function is not available if DHW mode is set;
3.
To activate this function, the unit must be enabled;
4.
The time bands apply to the current day only;
5.
If “Weekly timer”, “Preset mode“, “Clock timer”, “Temp. timer“ are set at the same
time, priority is given to the last one of these to be set;
6.
The setting is only valid if the unit is “On”;
7.
Depending on the operating mode defined (heating or cooling), the relative
set-points will be used;
8.
If the start time of “Period 2” is the same as that of “Period 1”, the first will be
implemented;
9.
The time bands are based on the timer inside the unit;
10.
During hot water production mode, this function is not available;