19
TECHNICAL DATA
indoor unit
EWA 120 H - EXC 123
CXS H unit that can be combined
CXS 1207 H
COOLING
❄
Refrigerating power
W
3200
❄
Moisture removed
l/h
0.8
❄
Total input power
W
1200
❄
E.E.R.
2.67
❄
Total input power
A
5.8
Heating
❊
Heating capacity
W
3500
❊
Total input power
W
1060
❊
C.O.P.
3.30
❊
Total input power
A
5.2
Air flow rate CXS-H unit
m
3
/h
1130
Max. effective static pressure
CXS-H unit
Pa
30
Rotary compressor type
Refrigerant charge
(R407C)
900
Maximum length of the refrigerant lines
m
10
Net weight of the CXS-H unit
kg
66
Power tension
: 1~ 230 V 50 Hz
The performance refers to the following conditions:
❄
room air temperature 27 °C B.S., 19 °C B.U. - outside air temperature 35 °C ;
❊
room air temperature 20 °C - outside air temperature 7 °C B.S., 6 °C B.U. ;
maximum speed;
Refrigerant line length 7.5 m.
-5
0
5
7
10
2500
2000
3000
3500
700
800
900
1000
1100
Outdoor air temperature [°C]
HEATING CAPACITY
AND TOTAL ELECTRIC INPUT POWERS
25
30
35
40
3000
3200
3400
3600
3800
1000
1100
1200
1300
REFRIGERATING CAPACITY
AND TOTAL ELECTRIC INPUT POWERS
Input power[W]
Outdoor air temperature [°C]
Heating capacity [kW]
Input power[W]
Refrigerating capacity [W]
OPERATIONAL LIMITS
TEMPERATURE
INDOOR
OUTDOOR
MAX COOLING
32°C BS-TK / 23°C BH-FK
43°C BS-TK
MIN 21°C BS-TK / 15°C BH-FK
21°C BS-TK
MAX HEATING 27°C BS-TK / 18°C BH-FK
24°C BS-TK
MIN 20°C BS-TK / -9.5°C BH-FK
-8.5°C BS-TK
Содержание CXS 1207 H
Страница 63: ...63 ...