27
After accessing the "Water tank" function, you can
specify whether the DHW storage tank accessory is in-
stalled in the system (for more information about the
assembly and use of the DHW storage tank accessory,
refer to the installation manual). Make your selection,
then press “OK” to confirm.
Water tank
With
Without
OK
Cancel
NOTES:
1.
If the compatible Aermec accessory tank is not installed, operating modes involving DHW produc-
tion will NOT be available.
2.
If the relative function is activated (paragraph 8.3), the value of these parameters will be stored in the
memory and automatically reset after any possible voltage failure.
7.6.
Set the installation of a compatible Aermec accessory tank (DHW tank)
After accessing the "Thermostat" function, you can
specify which type of management to apply to a hy-
pothetical external thermostat (for more information
about the assembly and use of an external thermostat,
refer to the installation manual). Make your selection,
then press “OK” to confirm.
Thermostat
Air
Air + hot water
Without
OK
Cancel
NOTES:
1.
The available options depend on the settings associated with the production of domestic hot water
(presence of a compatible Aermec accessory tank, etc.);
2.
To change the thermostat settings, the unit must be switched off.
3.
If the “Floor debug” or “Emergen. mode“ function is active, the external thermostat cannot be used.
4.
If the use of an external thermostat is activated, the commands for changing the operating mode or
for switching the unit on/off from the control panel will not be available.
5.
If the external thermostat is set for “Cool+hot water”, and the unit is “Off” because of the thermostat,
any requests from the DHW side will be met automatically by the unit, even though the display does
not show the “On” status (but you can still see the values in the parameters menu while the unit is
working).
6.
To pass from one setting value to the other, first of all select “Without“.
7.
If a unit on which the thermostat has been installed and set is disabled, the unit will automatically
be switched OFF.
8.
If the relative function is activated (paragraph 8.3), the value of these parameters will be stored in
the memory and automatically reset after any possible voltage failure.
7.7.
Setting the use of an external thermostat (Thermostat)
Содержание BHP Series
Страница 1: ...USER MANUAL 6228081_03 2020 02 20 08 52 0 0 C 0 0 C 25 C EN HMI series BHP series...
Страница 41: ......
Страница 42: ......
Страница 43: ...43...