54
VIOLATION MODES
Violation Modes that the ATMOS 2 can enter are termed - Conditional, Delayed, and Immediate.
Permanent Violation Mode and Gauge Mode are continuations of these.
While in Violation Modes, the Alternate Displays previously described can be accessed using
the Advance (Front) button, and the Backlight can be activated using the Select (Side) button.
While in Violation Modes, the ATMOS 2 will automatically revert to the Main Display after
3 seconds unless the Advance (Front) button is pressed to view another display of information.
Conditional Violation Mode
The ATMOS 2 will enter the Conditional Violation Mode
if you
ascend to a depth shallower
(Fig. 52a
)
than the Required De-
compression Ceiling
Stop Depth displayed (Fig. 52b).
Unless set OFF (a user setting), the Audible Alarm will emit a
continuous tone for 30 seconds or until acknowledged by pressing
the Advance (Front) button.
The Down Arrow, Deco Bar, and the Total Ascent Time display
will flash until you descend below the Required Stop Depth.
Also displayed will be Current Depth and applicable bar graphs.
If you descend below the required decompression ceiling before 5
minutes have elapsed, the ATMOS 2 will continue to function in
Decompression Dive Mode. In this case, no off-gassing credit will
be given, and for each minute above the ceiling 1
1
/
2
minutes of
Penalty Time
will be added to Required Stop Time.