OPERATION AND OPERATOR CONTROL
Page 9 of 15
Membrane key "Info"
Duration 5 seconds
Press 1x
Total delivery volume of the pump
(value not erasable)
Delivery volume since last
switching-on of device
Membrane key "P"
Press
Pump switches on and runs as long
as the key is kept pressed,
indicator flashes
Commissioning
To commission the air water separator VT2 proceed as follows:
1.
Connect the water separator VT2 electrically, s. page 7.
2.
Ensure that the waste water hose has been connected to the threaded connector
for waste water.
3.
Ensure that the air tube has been connected to the connector for the compressor
(s. page 5, Fig. 1, item 2) and to the air intake pipe on the compressor.
4.
Ensure that the compressor (soundbox VP2/VP3/ VP6) has been connected to the
appliance socket of the water separator VT2.
5.
Switch on the water separator VT2 via the "On / Off" switch (s. page 5, Fig. 1, item 1).
The following indication appears in the display:
Software version
Serial number of electronics system
After booting the following indication appears in the display:
Time in h
Pump cycle volume in liters
PG = 54621.0l
435.8l
00:00 h
0 l
VT2 V 2.0
SN 123456
Pump
active