Faults
Problem
Possible cause
Remedial action
Pump does not run
Dehumidifier not swit-
ched on
Switch on the dehumidifier.
Pump kit not properly
connected
Check connections.
The pump kit is con-
stantly on and does
not switch on or off
using the switch
Contact AERIAL Service.
Pump defect
Contact AERIAL Service.
‘Pump def’ is indi-
cated on the display
of the dehumidifier
Level switch in the
pump not switching
Contact AERIAL Service.
Pump dirty
Clean drip tray.
Hose blocked
or bent
Check hose.
Delivery head excee-
ded
Correct delivery head if neces-
sary.
Pump defect
Contact AERIAL Service.
11 Decommissioning, storage and disposal
Decommissioning and storage
ATTENTION! Device may be dam-
aged if stored improperly
Never store pump kit below freez-
ing.
Procedure
1. Remove the pump kit from the de-
humidifier if necessary.
2. Store pump kit b3°C and
+40°C.
Disposal
ATTENTION! Risk from materials and
substances
Sort materials according to type and
recycle in accordance with local reg-
ulations.
When disposing of auxiliary and
operating materials, observe the lo-
cal regulations and information on
the safety data sheets.
Do not dispose of the
pump kit as household
waste but rather in accord-
ance with legal regula-
tions.