AERA ZQ 032 Скачать руководство пользователя страница 10

24

GB

25

HOW TO USE / TECHNICAL DATA / ADVICE 

ON DISPOSAL

Cleaning of floor coverings

•  Work swiftly when treating areas of sealed 

wooden and parquet flooring, since the heat 

and moisture may attack the sealing and 

damage the material.

•  For ingrown or gloss-treated flooring, the shine 

may be lost following heat and steam treatment. 

With this in mind, always conduct a test on an 

inconspicuous area before proceeding.

•  Ensure you work swiftly when treating plastic 

flooring and do not expose the material to heat 

for too long. Heating too strongly may cause 

softening of the material and affect the surface 

structure.

ADVICE ON DISPOSAL

•  Electrical appliances should not be placed with household trash. It has been specified 

by law that old appliances must be disposed of via public community collection centres 

or bulky waste collection.

•  This is the only way to ensure that old appliances are disposed of professionally and 

utilized.

TECHNICAL DATA

MODEL 

ZQ 032

Voltage 

220 - 240 V 

~

 50 Hz

Rated output 

1800 Watts

Water capacity 

max. 500 ml

Operating pressure 

3.0 bar

Max. operating time 

40 Min.

Safety class 

I

30777-English_2 .indd   24

27/2/07   9:28:48 AM

Содержание ZQ 032

Страница 1: ...15 GB Steam cleaner Instruction manual Model ZQ 032 30777 English_2 indd 15 27 2 07 9 28 46 AM ...

Страница 2: ...bserve all instructions when using the device Please keep this instruction manual in a safe place for future reference When this device is passed on to another person please also supply this instruction manual with the device IMPORTANT SAFETY INSTRUCTIONS 17 DEVICE OVERVIEW 19 OPERATING THE DEVICE 19 USE OF ACCESSORIES 21 CARE AND MAINTENANCE 22 HOW TO USE 24 TECHNICAL DATA 24 ADVICE ON DISPOSAL 2...

Страница 3: ...r heater Before filling or refilling the device always switch it off and unplug from the mains supply Before opening the safety catch the steam pressure within the device must be reduced and the device be allowed to cool for at least 15 minutes If the device remains very hot there is the risk of water spraying back out when it is filled Always be careful when opening the safety catch since a lefto...

Страница 4: ...y after use and before stowing them away When storing wind the cord loosely around the device Be careful when doing so to ensure the cord is not exposed to excess tension Always store the device indoors in a cool dry and well ventilated location Repairs Never use the device when there is any sign of damage when it has fallen down or fails to work perfectly Regularly check the device power cord as ...

Страница 5: ...unplug from the mains supply Subsequently the steam pressure present in the device must be reduced To do so press the steam control on the handle until the remaining steam has escaped Before opening the safety catch the steam pressure within the device must be reduced and the device be allowed to cool for at least 15 minutes If the device remains very hot there is the risk of water spraying back o...

Страница 6: ...ted i e place the floor wiper onto the surface to be treated and start the steam treatment by pressing the steam delivery button In order to maintain the operating temperature and the required steam pressure the device continues heating regularly during operation During this process the red heat indicator lamp lights up The maximum operating time for the device is 40 minutes When the amount of ste...

Страница 7: ...The floor wiper is designed to clean heat and damp proof floor coverings including e g Cleaning of stone tiled and PVC floors Cleaning of sealed wooden and parquet flooring The floor wiper can be attached to the handle using the two extension pipes To connect the extension pipes together and with the handle press the adjustment knob so that both parts can be fitted together Insert the extension pi...

Страница 8: ...be used to treat delicate surfaces CARE AND MAINTENANCE Rinsing out the water heater Deposits in the water heater mean this should be regularly rinsed out after it has been filled 10 15 times Switch off the device unplug from the mains and allow the device to cool down thoroughly Once the device has cooled down and the excess steam has been released open the safety catch and fill the water heater ...

Страница 9: ...towing them away Do not allow brush attachments to rest on their bristles after they have cooled and dried since the pressure could deform them Care of the floor cloth To guarantee the cleaning power and longevity of the microfiber cloth please adhere to the following guidelines Wash and dry new microfiber cloths before using for the first time Clean the microfiber cloth at a temperature of 60 C i...

Страница 10: ...do not expose the material to heat for too long Heating too strongly may cause softening of the material and affect the surface structure ADVICE ON DISPOSAL Electrical appliances should not be placed with household trash It has been specified by law that old appliances must be disposed of via public community collection centres or bulky waste collection This is the only way to ensure that old appl...

Страница 11: ...e g over voltage lightning Commercial use of the device Your statutory rights in the case of any deficiency in the device subsequent delivery cancellation deterioration compensation and so on in accordance with 437 BGB will remain unaffected by this guarantee Please retain the original packaging in case the product needs to be returned for repair Repaired or exchanged components are generally cove...

Страница 12: ...30777 English_2 indd 26 27 2 07 9 28 48 AM ...

Отзывы: