AEQ
LIVE 20 TR
.
16
5.4 INDICATIONS
LED “STATUS” flashes green at one-second intervals:
o
The CH-20 is ready for use
LED “STATUS” glow green constantly after the “START” button is
pressed:
o
The CH-20 is in the automatic detection process
(may take up 5 minutes)
LED “STATUS” flashes 3 times green to indicate the number of cells
inside the DR-202 (3 cells):
o
The charge process start.
LED “STATUS” flashes orange and beeper sound:
o
To indicate the DR-202 battery is approximately 95% fully
charged.
LED “STATUS” flashes orange to indicate 3 cells inside DR-202 and
beeper sounds:
o
The charge process is completed
LED “STATUS” flashes red and beeper sounds:
o
There are an error message with the following cases:
Battery broken
Input voltage too low
Reverse polarity at input
Circuit broken at charge output
Short circuit at charge output
Maximum charge time exceeded (3 hours)
Battery bad contact
IMPORTANT NOTE:
We recommend making two or three complete charge processes to assure an
optimal yield of the DR-202 battery.
The cable of the feeder to the cable of charge of the LIVE 20 TR NEVER must
be connected directly.