18
SW2-5
SW2-4
SW2-3
Scale type
OFF
OFF
OFF
AES
OFF
OFF
ON
DIN
OFF
ON
OFF
VU
OFF
ON
ON
BBC
ON
OFF
OFF
Extended VU
ON
OFF
ON
NORDIC
ON
ON
OFF
No scale
ON
ON
ON
No scale
Note:
The OFF position is obtained with a switch lever in the direction of the arrow, (to the
right in the above drawing).
The bargraph displays have 26 LEDs. The bottom LED in each bar is reserved for the audio
alarm. The remaining 25 LED level segments may be assigned to three colored zones, red,
amber and green.
Up to 25 of the top most segments may be colored red. Up to 25 segments from the end of
the red zone downward may be colored amber and the remaining segments (if any) are
always green.
Choosing how many segments are colored red from the top of the bargraph sets the .red
zone. Select from none to 25 using SW2-2, SW2-1, SW6-8, SW6-7 and SW6-6 as follows:
SW2-2
SW2-1
SW6-8
SW6-7
SW6-6
Segment from bargraph top
OFF
OFF
OFF
OFF
OFF
None
OFF
OFF
OFF
OFF
ON
1
OFF
OFF
OFF
ON
OFF
2
OFF
OFF
OFF
ON
ON
3
OFF
OFF
ON
OFF
OFF
4
OFF
OFF
ON
OFF
ON
5
OFF
OFF
ON
ON
OFF
6
OFF
OFF
ON
ON
ON
7
OFF
ON
OFF
OFF
OFF
8
OFF
ON
OFF
OFF
ON
9
OFF
ON
OFF
ON
OFF
10
OFF
ON
OFF
ON
ON
11
OFF
ON
ON
OFF
OFF
12
OFF
ON
ON
OFF
ON
13
OFF
ON
ON
ON
OFF
14
OFF
ON
ON
ON
ON
15