‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange.
Parameter Number Size (Byte)
Available Settings
Default value
15
1
0 ~ 8
0
14)
Temperature Scale Setting
Configure temperature sensor scale type, Temperature to report in Celsius or Fahrenheit.
0 – Celsius (C).
1 – Fahrenheit (F).
Parameter Number Size (Byte)
Available Settings
Default value
20
EU/AU 1
0, 1
0
US
1
0, 1
1
15)
Temperature Threshold Value to Report
Change threshold value for change in temperature to induce an automatic report for
temperature sensor. Scale is identical setting in Parameter No.20.
Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20)
to induce automatic report or setting a value of 2 will be a change of 0.2(C or F).
Parameter Number Size (Byte)
Available Settings
Default value
21
2
0~ 250
20
16)
Light intensity Threshold Value to Report
Change threshold value for change in light sensor to induce an automatic report for
temperature sensor. Scale: Lux.
Parameter Number Size (Byte)
Available Settings
Default value
22
2
0~ 10000
100
17)
Temperature Sensor Report Interval
This parameter is configured the time interval for temperature sensor report. This value is
larger, the battery life is longer. And the temperature value changed is not obvious.
Unit: Second.
Parameter Number Size (Byte)
Available Settings
Default value
23
2
1 - 32767
3600
18)
Light Sensor Report Interval
This parameter is configured the time interval for light sensor report. This value is larger, the
battery life is longer. And the light intensity changed is not obvious.
Unit: Second.
Parameter Number Size (Byte)
Available Settings
Default value
24
2
1 - 32767
3600