1)
Motion Retrigger Time
This parameter is configured the delay time before PIR sensor can be triggered again to
reset motion timeout counter. Value = 0 will disable PIR sensor from triggering until motion
timeout has finished.
Parameter Number Size (Byte)
Available Settings
Default value
1
2
0 ~ 32767
30
2)
Motion Clear Time
This parameter is configured the time to clear motion event after a motion event detected.
Time to motion clear, the device will send a clear event report to controller and send BASIC_SET
= 0x00 to nodes associated in group 2. Unit: Second.
Parameter Number Size (Byte)
Available Settings
Default value
2
2
1 ~ 32767
240
3)
Motion Sensitivity
This parameter is configured the sensitivity that motion detect.
0 – PIR sensor disabled.
1 – Lowest sensitivity.
11 – Highest sensitivity.
Parameter Number Size (Byte)
Available Settings
Default value
3
1
0 ~ 11
11
4)
Binary Sensor Report Enable
‘0’ –Disable sensor binary report when motion event is detected or cleared.
‘1’ –Enable sensor binary report when motion event is detected or cleared.
Parameter Number Size (Byte)
Available Settings
Default value
4
1
0 , 1
0
5)
Disable BASIC_SET to Associated nodes
This parameter is configured the enabled or disabled send BASIC_SET command to nodes
that associated in group 2 and group 3.
0 – Disabled All Group Basic Set Command
1 – Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is
disabled. 2 – Enabled Group 3 Basic Set Command, Group 2 Basic Set
Command is disabled. 3 – Enabled Group 2 and Group 3 Basic Set Command.
Parameter Number Size (Byte)
Available Settings
Default value
5
1
0 ~ 3
3