Parameter 111: Set the interval of automatic report for Report group 1. 

Set the interval of automatic report for Report group 1.

 

Size: 4 Byte, Default Value: 3 

Setting 

Description 

1 - 2147483647 

The range of interval time is 1 to 2147483647. 

Parameter 112: Set the interval of automatic report for Report group 2. 

Set the interval of automatic report for Report group 2.

 

Size: 4 Byte, Default Value: 600 

Setting 

Description 

1 - 2147483647 

The range of interval time is 1 to 2147483647. 

Parameter 113: Set the interval of automatic report for Report group 2. 

Set the interval of automatic report for Report group 3.

 

Size: 4 Byte, Default Value: 600 

Setting 

Description 

1 - 2147483647 

The range of interval time is 1 to 2147483647. 

Parameter 120: Configure the external switch mode for S1. 

Configure the external switch mode for S1.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Enter automatic identification mode 

Momentary push button mode 

3 way switch mode 

2-state switch mode 

Parameter 121: Configure the external switch mode for S2. 

Configure the external switch mode for S2.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Enter automatic identification mode 

Momentary push button mode 

3 way switch mode 

2-state switch mode 

Parameter 122: Set the control destination for external switch S1 

Set the control destination of the external switch.

 

Size: 1 Byte, Default Value: 3 

Setting 

Description 

control the output loads of itself. 

control the other nodes 

control the output loads of itself and other nodes. 

Содержание ZW116

Страница 1: ...resulting from failure to comply with the instructions in this manual or any other material Use this equipment only for its intended purpose Follow the disposal instructions Do not dispose of electron...

Страница 2: ...s to control the load ON OFF independently Its surface has a pin socket which can be used for connecting to the touch panel so you can also use the touch panel to control the Nano Switch The Nano Swit...

Страница 3: ...load 1 S2 External switch control for load 2 1 Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not short circuited during the installation w...

Страница 4: ...the following diagram to achieve this Note The IN terminal should be connected to the of DC 24V input Wiring diagram of DC24V power input Since the Nano Switch also supports the DC24V power input so y...

Страница 5: ...ions 2 Press the button 2 times quickly on the Nano Switch Exclusion 1 Press the button once on the Dual Nano Switch Quick trouble shooting Here are a few hints for network installation if things dont...

Страница 6: ...or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired v...

Страница 7: ...Value 1 Setting Description 0 Send Nothing 1 Send Basic Set CC Parameter 82 To set which notification would be sent to the associated nodes in association group 4 To set which notification would be se...

Страница 8: ...value Mon to Sun 16777215 Disable the setting 16777216 Enable the setting Parameter 90 Enables disables parameter 91 and 92 below Enables disables the function of parameter 91 and 92 Size 1 Byte Defau...

Страница 9: ...n Report group 2 To set which reports need to be sent in Report group 2 Size 1 Byte Default Value 0 Setting Description 1 Send Meter Report of voltage V 2 Send Meter Report of current A 4 Send Meter R...

Страница 10: ...2147483647 The range of interval time is 1 to 2147483647 Parameter 120 Configure the external switch mode for S1 Configure the external switch mode for S1 Size 1 Byte Default Value 0 Setting Descripti...

Страница 11: ...ing and removed from the z wave network Technical Data Dimensions 0 0425000x0 0400000x0 0200000 mm Weight 28 5 gr Hardware Platform ZM5202 EAN 1220000015333 IP Class IP 20 Voltage 24V DC 230V AC Load...

Страница 12: ...ves can be sensors actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network In...

Отзывы: