Aeotec by Aeon Labs Bypass.
Aeotec Bypass is a capacitive device and can only be
used for Aeotec Nano Dimmer. When your Nano Dimmer
connects LED lights or energy saving compact fluorescent
lamps, the Bypass can prevent flickering of the LED light
when dimming off the light and glowing of the turned off
compact fluorescent lamp.
When the Nano Dimmer is installed by 2-wire system, you
may need to connect a low power load (E.g. an LED light
or compact fluorescent lamp within 4W) to be controlled.
In this case, the Nano Dimmer may not get enough power
from the AC power supply, so a bypass can be added
to act as a dummy load to help your Nano Dimmer get
enough power from the power supply.
Familiarize yourself with your Bypass.
Warning: The main circuit breaker or fuse must be shut off
during the Bypass installation.
1. Install the Bypass in parallel with the bulb load.
2. Install the Bypass on the Nano Dimmer’s terminals.
Use the wire stripper or wire knife to peel off the
insulated part and then expose the metal part of the
Bulb’s 2 connection wires.
Note: this Bypass installation can only be used when your
Nano Dimmer is installed by the 3-Wire system (as shown
in diagram below).
In 3-Wire system, the Bypass can be connected to
the Nano Dimmer’s “N” and “OUT” terminals directly if
needed. As shown below:
Model number: ZW150
Connect the Bypass to the Bulb’s 2 connection wires,
as shown below:
Use the insulation tape to wrap the connection points to
avoid electric leakage or electric shock.
a.
b.
c.
(Wiring diagram of 3-Wire system)
(Wiring diagram of 2-Wire system)
Technical specifications.
Install Bypass.
Bypass
1
2
3
L
N
COM
OUT
S1 S2
Touch panel
Live
Bypass
Neutral
Touch
panel
Live
Neutral
L
N
COM
OUT
S1
S2
Bypass
Bypass
(Wiring diagram of 3-Wire system)
L
N
COM
OUT
S1 S2
Touch panel
Live
Neutral
L
N
COM
OUT
S1 S2
Touch panel
Live
Bypass
Neutral
Power input: 120VAC to 240VAC, 50Hz/ 60Hz.
Max power consumption: 1W.
Operating temperature: 0°C to 40°C /32°F to 104°F.
Relative humidity: 8% to 80%.
Dimensions:19.2×26.7×10.6mm
Warranty.
If you are in need of any technical support during or
subsequent to your products’ warranty, please get in
touch with our support team via http://aeotec.com/
support. The Company you bought this product from has
also guaranteed to assist you with any of your support
needs, and you can also contact them for accordingly.
This guarantee made by the company who you purchased
the product from includes the transfer of Aeon Labs’ full
warranty to that Company. They’ve guaranteed that they’ll
be able to assist you, the Customer, with all technical
support and repair needs on our behalf.
Aeon Labs warrants to the original purchaser of Products,
that is the Company who you have purchased from,
that for the Warranty Period (as defined below), the
4
Содержание Aeotec Bypass
Страница 1: ...View the expanded manual http aeotec com support Bypass...
Страница 4: ...Wiring diagram of 2 Wire system Touch panel Live Neutral L N COM OUT S1 S2 Bypass...
Страница 16: ......