 Z-Wave devices control other Z-Wave devices. The relationship between one device controlling 

another device is called association. In order to control a different device, the controlling device needs to 

maintain a list of devices that will receive controlling commands. These lists are called  association groups 

and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event 

happens all devices stored in the respective association group will receive a common wireless command.

Association Groups:

1

Devices to be switched on upon motion deteced and off after a timeout (on time) (max. nodes in 

group: 5)

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can 

adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128 

… 255 the value sent in the application shall be the desired value minus 256. For example: to set a 

parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value 

the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Sensor report type on Get without instances (Parameter Number 1, Parameter Size 1) Which type of multi 

sensor report should be sent on multi sensor Get command without instances

Value

Description

0

Temperature, humidity and luminance (Default)

1

Temperature

2

Luminance

3

Humidity

Wake up 10 minutes when batteries are inserted (Parameter Number 2, Parameter Size 1) Stay awake for 

10 minutes after batteries are inserted

Value Description

0

No (Default)

1

Yes

On time (Parameter Number 3, Parameter Size 2) How long should the device associated to multi senor 

keep state On before sending it Off command (if the value is bigger than 255, the value would be rounded to 

next integer in minutes)

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 5 

Содержание AEO MULTISENS

Страница 1: ...en the sensor detects IR changes in front of its viewing window The Aeon Labs Multisensor complies with the IP43 standard so it can be used outdoors By adjusting the sensitivity of the sensor you can avoid the triggering due to small animals like dogs or cats The Aeon Labs Multi Sensor is delivered with a swivelling Back Mount Arm for wall mount and a Back Mount Plate for ceiling mount Installatio...

Страница 2: ...and rain b For ceiling mount use the screws with the Back Mount Plate 4 Mount the Multisensor on the Mount Plate by rotating it clockwise to the Lock sign The next pictures are showing the effective motion sensor range for ceiling and wall mounting c 2016 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 2 ...

Страница 3: ...r controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controll...

Страница 4: ...tate by sending out a so called Wakeup Notification The controller can then empty the mailbox Therefore the device needs to be configured with the desired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the des...

Страница 5: ...et values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Sensor report type on Get without instances Parameter Number 1 Parameter Size 1 W...

Страница 6: ...olicited reports periodicaly Intervcal group 2 Parameter Number 102 Parameter Size 4 Which reports need to send automatically in timing intervals for group 2 Value Description 0 Battery report Default 5 Temperature 6 Luminosity 7 Humidity Send unsolicited reports periodicaly Intervcal group 3 Parameter Number 103 Parameter Size 4 Which reports need to send automatically in timing intervals for gro...

Страница 7: ...meter Number 112 Parameter Size 4 Interval to send out reports to timing group 2 Value Description 1 2678400 sec Default 720 Unsolicitate reports interval for timing groups 3 Parameter Number 113 Parameter Size 4 Interval to send out reports to timing group 3 Value Description 1 2678400 sec Default 720 Technical Data c 2016 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All right...

Страница 8: ...r Frame Support No SDK 5 03 Device Type Slave with routing capabilities Generic Device Class Multilevel Sensor Specific Device Class Routing Multilevel Sensor Routing Yes FLiRS No Firmware Version 1 18 c 2016 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 8 ...

Отзывы: