6
Charging the Battery
Fully charge the battery before first use.
NOTE:
A full recharge of a completely discharged battery takes approximately 5 hours.
To recharge the battery:
1. Unscrew the cover of the battery charging
connector.
2. Connect the supplied power cord to the
instrument and AC power.
3.
The button lights and will go out when
the power cord is disconnected.
Button Functions
BUTTON
DESCRIPTION
Return to previous menu.
Display Configuration menu for instrument setup.
Take a snapshot of the current screen or access screens already stored
in the memory.
Open a Help screen describing the current function.
Transients or Inrush Current
:
Waveform acquisition mode, with two sub-modes: transients mode
(blackouts, interference, etc.) and inrush current mode (starting of motor).
Harmonics Mode
:
Displays the harmonics in percent and value ratios for voltage, current and
power for each harmonic through the 50
th
.
Determines harmonic current produced by non-linear loads.
Analyzes problems caused by harmonics according to their order (heating of
neutrals, conductors, motors, etc.).
Waveforms Mode:
Displays voltage and current waveforms or vector representation.
Identifies signal distortion signatures.
Displays of amplitude and phase unbalance for voltage and current.
Checks connections for correct phase order.