Megohmmeter Models 6526 & 6534 - Quick Start Guide

PRECAUTIONS FOR USE

This instrument is compliant with safety standard IEC 61010-2-030, and the 

leads are compliant with IEC 61010-031, for voltages up to 600 V in CAT IV or 

1000 V in CAT III. 

Failure to observe the safety instructions may result in electric shock, fire, 

explosion, destruction of the device, or destruction of the installations.

 

Carefully read and understand all precautions for use.

 

Be aware of all electrical hazards when using this instrument.

 

Using this instrument other than as specified may compromise the 

instrument’s user protection features.

 

The safety of any system in which this instrument is incorporated is the 

responsibility of the integrator of the system.

 

This instrument can be used on CAT IV installations, for voltages not 

exceeding 600 V

RMS

 with respect to ground or 700 V

RMS

 maximum between 

terminals.

 

Do not use the instrument on networks whose voltage or category exceeds 

those specified in this manual.

 

Observe all environmental conditions of use.

 

Except for voltage measurements, take no measurements on electrically “live” 

systems.

 

Do not use the instrument if it appears damaged, incomplete, or poorly closed.

 

Before each use, check the condition of the insulation on the leads, housing, 

and accessories. Any part on which the insulation is deteriorated (even 

partially) must be set aside for repair or scrapping.

 

Using the instrument without its battery compartment cover may result in 

electric shock to the user.

 

Before using your instrument, ensure it is completely dry.

 

Use only the leads and accessories supplied. The use of leads (or other 

accessories) of a lower voltage rating or category limits the use of the 

instrument/leads (or accessories) combination to the lowest category and 

service voltage.

 

When handling the leads, test probes, and alligator clips, keep your fingers 

behind the physical guards.

 

Before removing the battery compartment cover, ensure all measurement 

leads and accessories are disconnected. Replace all batteries at once. Use 

alkaline batteries.

 

Use personal protection equipment where appropriate.

 

All troubleshooting and metrological checks must be done by competent, 

accredited personnel.

Содержание 6526

Страница 1: ...Megohmmeter Models 6526 6534 Quick Start Guide ENGLISH WITH AEMC INSTRUMENTS MEGOHMMETERS ...

Страница 2: ...742 2346 This documentation is provided as is without warranty of any kind express implied or otherwise Chauvin Arnoux Inc has made every reasonable effort to ensure that this documentation is accurate but does not warrant the accuracy or completeness of the text graphics or other information contained in this documentation Chauvin Arnoux Inc shall not be liable for any damages special indirect in...

Страница 3: ...time of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For recalibration please use our calibration services Refer to our repair and calibration section at www aemc com Serial Catalog 2155 53 2155 55 Model 6526 6534 Pl...

Страница 4: ...Model 6534 Cat 2155 55 1 4 GB USB Drive with User Manual Dataview Software Also Included 1 6 AA Batteries Soft Carrying Pouch 7 75 x 9 25 x 2 75 in Cat 2119 02 2 Color coded Grip Probes Cat 2152 26 Model 6534 Only 2 Color coded Red Black Test Leads with Alligator Clips and 1 Black Test Probe Cat 2152 26 ...

Страница 5: ...gn approach in order to design this instrument Analysis of the complete lifecycle has enabled us to control and optimize the effects of the product on the environment In particular this instrument exceeds regulation requirements with respect to recycling and reuse This product complies with the Low Voltage Electromagnetic Compatibility European directives 73 23 CEE 89 336 CEE In the European Union...

Страница 6: ...ve all environmental conditions of use Except for voltage measurements take no measurements on electrically live systems Do not use the instrument if it appears damaged incomplete or poorly closed Before each use check the condition of the insulation on the leads housing and accessories Any part on which the insulation is deteriorated even partially must be set aside for repair or scrapping Using ...

Страница 7: ...switch to choose the function or to turn the instrument OFF The table below lists the functions available for each model instrument SET UP V OFF Ω 250V 500V 1000V MΩ V kΩ MR OFF Ω 100V 250V 500V 1000V 50V TEST HOLD 0 MEGOHMMETER MODEL 6526 G nF µF M VDC AC k ALARM MEM DARPI T1T2 k M mAµA G VHz G M HOLD P REL CLR REL G M VDC AC k M mAµA G VHz G M HOLD P ALARM 1 2 3 4 5 ...

Страница 8: ...ond function is marked under the key and is enabled by a long 2 seconds press Selects the PI and DAR functions Toggles backlighting ON and OFF HOLD Freezes unfreezes the displayed measurement on the LCD SET UP Accesses the instrument s setup parameters and information 0 Applies lead compensation for use in continuity testing Activates deactivates alarms and The and keys allow you to Select the dis...

Страница 9: ...the root directory and double click it to run the installation program 4 The DataView setup screen appears In the upper left section of the screen choose the language version of the setup program Then select DataView in the Options list and click Install 5 Click OK to confirm setup The InstallShield Wizard welcome screen appears The InstallShield Wizard leads you through the installation process A...

Страница 10: ...ssions creating DataView reports from the downloaded data and configuring the instrument through the Control Panel Recording Data Recording a measurement Press the MEM key for 2 seconds The measurement is stored in the first available location in the instrument s memory The saved recording includes all information associated with the measurement including voltage current duration of tests T1 and T...

Страница 11: ...as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA Send an email to repair aemc com requesting a CSA you will be provided a CSA Form and other required paperwork along with the next steps to complete the request Then return the instrument along with the signed CSA Form This ...

Страница 12: ...s limited warranty is given by AEMC Instruments not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments Full warranty coverage and product registration is available on our website at www aemc com warranty html Please print the online Warranty Coverage Information for y...

Страница 13: ...steps to complete the request Then return the instrument along with the signed CSA Form Please write the CSA on the outside of the shipping container Return the instrument postage or shipment pre paid to Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 E mail repair aemc com Caution To protect yourself ag...

Страница 14: ...NOTES ...

Страница 15: ...NOTES ...

Страница 16: ...C Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 800 343 1391 Fax 603 742 2346 www aemc com 05 23 99 MAN 100434 v07 04 2016 Chauvin Arnoux Inc d b a AEMC Instruments All Rights Reserved ...

Отзывы: