background image

Statement of Compliance

Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments 

certifies that this instrument has been calibrated 
using standards and instruments traceable to 
international standards.
We guarantee that at the time of shipping your 
instrument has met its published specifications.
The recommended verification interval for this 
instrument is 12 months and begins on the date 
of receipt by the customer. For verification, please 
use our calibration services. Refer to our repair 
and calibration section at 

www.aemc.com

.

Serial #: 

 ____________________________

Catalog #: 

 

2121.11

Model #:  6609

Please fill in the appropriate date as indicated:
Date Received:  ________________________
Date Verification Due:  _____________________

Chauvin Arnoux

®

, Inc. d.b.a AEMC

®

 Instruments

www.aemc.com

Содержание 2121.11

Страница 1: ...MOTOR ROTATION METER PROBADOR DE FASE ROTACI N DE MOTOR E N G L I S H User Manual E S PA O L Manual de instrucciones PHASE MOTOR ROTATION MODEL 6609 R TEST L2 B L3 C L1 A 600V CAT III 300V CAT IV L M...

Страница 2: ......

Страница 3: ...recommended verification interval for this instrument is 12 months and begins on the date of receipt by the customer For verification please use our calibration services Refer to our repair and calib...

Страница 4: ...ures 7 3 SPECIFICATIONS 8 4 OPERATION 9 4 1 Phase Rotation Direction 9 4 2 Indication of Direction of the Rotating Field or Direction of Rotation without Connecting Test Leads 10 4 3 Determining the D...

Страница 5: ...t equal to those of the instru ment and compliant with standard IEC 61010 031 Do not use if the cover of the battery compartment is missing or if the housing is damaged or not correctly closed Do not...

Страница 6: ...rial in compliance with Directive WEEE 2002 96 EC 1 2 Definition of Measurement Categories CAT I Measurement category I corresponds to measurements taken on circuits not directly connected to the netw...

Страница 7: ...ur distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate your claim 1 4 Ordering Information Phase and Motor Rotation Meter Model 6609 Cat...

Страница 8: ...pumps and other electrical devices interconnected on the power line system before installation NOTE The Model 6609 does not require fusing because the inputs are protected by a high impedance circuit...

Страница 9: ...ST L2 B L3 C L1 A 600V CAT III 300V CAT IV L M 1 2 3 4 7 6 5 Figure 1 1 Test lead input terminals 2 Phase indicators L1 L2 and L3 3 Green clockwise rotation LED 4 Red counter clockwise rotation LED 5...

Страница 10: ...o 400Hz Test Current 3 5mA Power Source 9V battery 6LR61 NEDA 1604 MECHANICAL Dimensions 5 1 x 2 7 x 1 3 130 x 69 x 32mm Weight 6 oz 170g ENVIRONMENTAL Operating Temperature 32 to 104 F 0 to 40 C Stor...

Страница 11: ...the 3 phases of the network to be tested 3 Press the ON TEST button The Green LED indicates that the instrument is in operation 4 When the indicators of all three phases are lit the clockwise or coun...

Страница 12: ...clockwise rotation indicator lights to indicate the direction of the rotating field Note The instrument does not work on motors controlled by frequency converters R The table below summarizes the con...

Страница 13: ...the right at a few RPM s to get a stable reading on one of the LED rotations 5 The clockwise or counter clockwise rotation indicator lights indicating whether or not the order of connection of the pha...

Страница 14: ...over Take out the battery and replace with a new 9V battery Type NEDA 1604 6LF22 6LR61 Replace the back cover on the case 5 2 Cleaning and Storage To avoid electrical shock or damage to the meter do n...

Страница 15: ...ng container Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Tel 800 945 2362 or 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 repair aemc com Or contact...

Страница 16: ...faulty material REGISTER ONLINE AT www aemc com Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or by...

Страница 17: ...19 2 2 Caracter sticas de los Controles 20 3 ESPECIFICACIONES 21 4 OPERACI N 22 4 1 Sentido de rotaci n de fases 22 4 2 Indicaci n del sentido del campo rotativo o sentido de rotaci n sin conexi n 23...

Страница 18: ...gor a al menos iguales a los del instru mento y que cumplan con la norma IEC 61010 031 No utilice el instrumento si la carcasa est da ada o mal cerrada No ponga los dedos a proximidad de los terminale...

Страница 19: ...om stico 1 2 Definici n de las Categor as de Medici n CAT I Medici n de la categor a I corresponde a las medicio nes adoptadas en relaci n con los circuitos que no est n directamente conectados Ejempl...

Страница 20: ...orte y avise inmediatamente a su distribuidor dando una descripci n detallada de cualquier da o 1 4 Informaci n de Pedidos Indicador de fases y de rotaci n modelo 6609 Cat N 2121 11 Incluye medidor co...

Страница 21: ...medir la rotaci n adec uada de los motores transportadores bombas y otros dispositivos el ctricos interconectados en el sistema de l nea de alta tensi n antes de la instalaci n NOTA El modelo 6609 no...

Страница 22: ...2 3 4 7 6 5 1 Terminal de entrada del cable de prueba 2 Indicadores de fase L1 L2 y L3 3 Indicador verde LCD de rotaci n en el sentido a las agujas del reloj 4 Indicador rojo LCD de rotaci n en contra...

Страница 23: ...a 3 5mA Alimentaci n Bater a 9V 6LR61 NEDA 1604 MECANICAS Dimensiones 5 1 x 2 7 x 1 3 130 x 69 x 32mm Peso 6 oz 170g MEDIO AMBIENTE Temperatura de Funcionamiento 32 hasta 104 F 0 hasta 40 C Temperatur...

Страница 24: ...las 3 fases de la red a probar 3 Pulse el bot n TEST El indicador luminoso verde indica que el instrumento est funcionando 4 Cuando los 3 indicadores de fases est n encendidos el indicador de rotaci...

Страница 25: ...con trario se enciende para indicar el sentido del campo rotativo Atenci n el instrumento no sirve para motores controlados por convertidores de frecuencia R La tabla a continuaci n resume las condici...

Страница 26: ...una lectura estable en una de las rotaciones del LED 5 El indicador de rotaci n en el sentido horario o en el sentido contrario se enciende para indicar si se ha respetado o no el orden de conexi n d...

Страница 27: ...de 9V tipo NEDA 1604 6LF22 6LR61 y vuelva a fijar la tapa mediante el tornillo ADVERTENCIA Desconecte siempre todas las pinzas de prueba antes de reemplazar la bater a o el fusible 5 2 Limpieza 1 Peri...

Страница 28: ...criba el CSA en el exterior del envase Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Tel 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 repa...

Страница 29: ...uando tengamos su TARJETA DE REGISTRO archivada AEMC Instruments reparar o reemplazar el material defectuosos a su discreci n Si no tenemos archivada su tarjeta de registro le pediremos un comprobante...

Страница 30: ......

Страница 31: ......

Страница 32: ...03 17 99 MAN 100337 v6 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA www aemc com...

Отзывы: