![AEM AQ-1 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/aem/aq-1/aq-1_instruction-manual_2860628013.webp)
13
10/25/2016 - DOCUMENT NUMBER: 10-2500
© 2016 AEM Performance Electronics
AQ-1 DATA LOGGER
Sensor Wizard
·
Load known sensor calibrations from Wizard database
·
Save custom sensor calibrations to Wizard database
Input Options
·
Choosing Invert will make an "OFF" at the pin to an "ON" in
the data log and vice versa
·
Digital inputs may be used as beacon inputs but with lower
timing accuracy than Frequency Inputs which makes them
more suitable for Log Markes than for lap timing
Configuration: Battery Voltage
This channel records the voltage that is applied Pin 1 - Switched 12V.
Channel Options
·
Enabled checkbox determines if channel is logged or not
·
The channel name is fixed at 'Battery Voltage'
·
Set the sampling rate of this input
Live Data
·
Displays the voltage level measured at the input pin
Configuration: Accelerometer
The internal 3-axis accelerometer (+/- 4g) requires a simple calibration procedure prior to use.
Channel Options
·
Enabled checkbox determines if channel is logged or not
·
The channel name(s) is fixed and will appear in the log as
'Accel Lateral', 'Accel Longitudinal', 'Accel Vertical'
·
Set the sampling rate of this input
Live Data
·
Perform calibration and ensure the AQ-1 is in the proper
mounting position
·
Displays the current acceleration measured by the logger
including Earth's gravity (Vertical = 1g)