1993–1998 Toyota Supra MKIV Twin Turbo
19
© 2015 AEM Performance Electronics
Infinity
Pin
Hardware Reference
7100-XXXX-62
7101-XXXX-63
Function
Hardware Specification
Notes
C1-41
+5V_Out_1
+5V Out
Regulated, f used +5V supply f or
sensor power
Analog sensor power
C1-42
+5V_Out_1
+5V Out
Regulated, f used +5V supply f or
sensor power
Analog sensor power
C1-43
HighsideSwitch_1
HS1 (switched 12V)
0.7A max, High Side Solid State
Relay
See Setup Wizard page 'HighSide
Assigment Tables' f or conf iguration
options. See 2D lookup table 'HS1_Table'
f or activ ation settings.
C1-44
HighsideSwitch_0
VTEC
0.7A max, High Side Solid State
Relay
See Setup Wizard page 'HighSide
Assigment Tables' f or conf iguration
options. See 2D lookup table 'HS0_Table'
f or activ ation settings.
See Setup Wizard page 'VTEC' f or def ault
activ ation criteria.
C1-45
Crankshaf t Position
Sensor VR+
Crankshaf t Position
Sensor VR+
Dif f erential Variable Reluctance
Zero Cross Detection
See Setup Wizard page Cam/Crank f or
options.
C1-46
Crankshaf t Position
Sensor VR-
Crankshaf t Position
Sensor VR-
See Setup Wizard page Cam/Crank f or
options.
C1-47
Camshaf t Position
Sensor 1 VR-
Camshaf t Position
Sensor 1 VR-
Dif f erential Variable Reluctance
Zero Cross Detection
See Setup Wizard page Cam/Crank f or
options.
C1-48
Camshaf t Position
Sensor 1 VR+
Camshaf t Position
Sensor 1 VR+
See Setup Wizard page Cam/Crank f or
options.
C1-49
VR+_In_2
Non Driv en Lef t
Wheel Speed Sensor
+
Dif f erential Variable Reluctance
Zero Cross Detection
See Non Driv en Wheel Speed Calibration
in the Setup Wizard Input Function
Assignment page.
C1-50
VR-_In_2
Non Driv en Lef t
Wheel Speed Sensor
-
C1-51
VR-_In_3
Driv en Lef t Wheel
Speed Sensor -
Dif f erential Variable Reluctance
Zero Cross Detection
See Driv en Wheel Speed Calibration in the
Setup Wizard Input Function Assignment
page.
C1-52
VR+_In_3
Driv en Lef t Wheel
Speed
C1-53
DBW1 Motor -
DBW Motor Control
Close
5.0A max Throttle Control
Hbridge Driv e
+12V to close
C1-54
DBW1 Motor +
DBW Motor Control
Open
5.0A max Throttle Control
Hbridge Driv e
+12V to open
C1-55
Power Ground
Ground
Power Ground
Connect directly to battery ground.
C1-56
Injector 6
Injector 6
Saturated or peak and hold, 3A
max continuous
Injector 6