30-0309 - BOOST/FUEL PRESSURE 15PSI SAE ONLY

Gauge Installation

Installation using supplied bracket

Installation w ithout bracket, using rubber band

A 2-1/6" (52mm) hole is required to mount the X-Series gauge.  A bracket and thumbscrews are provided to facilitate
installation into a panel or gauge pod.  In some cases, the gauge cup may be pushed into a mounting  hole  causing  an
interference fit strong enough to retain the gauge; the supplied rubber band may be fit to the gauge to create a tighter fit in
mounting holes slightly larger than 52mm.  It is, however, recommended that gauges be mounted securely  using  the
supplied bracket to ensure they never become loose and cause a hazard during vehicle operation.

Note: 

The gauge is not water-proof and should not be installed in a location with exposure to water or snow.  Damage

caused by water ingress will not be covered under warranty.

0-5V Analog Output

WHITE WIRE = Analog Po
BROWN WIRE = Analog Negative -

0-5V Analog Output Scaling Formulas

psig

=

(3.75 * Volts) -1.88

bar

=

(0.26 * Volts) - 0.13

The 0-5V analog output is suitable for output to devices such
as loggers or ECUs.  This differential output requires special
care to ensure proper operation.  The WHITE  signal  wire
should be connected to the positive of the analog input of the
logging device or ECU; the BROWN wire must be connected
to the negative of the analog input of the logging device or
ECU.  If the logging device or ECU  does  not  have  a
differential  analog  input  (both  a  dedicated  positive  and
negative terminal for the analog  input)  then  connect  the
BROWN wire to the shared signal ground.  If the device does
not have a dedicated signal ground then as a last course  of
action, connect it to the power ground of the logging device.

Important Note

: If bench testing the analog output outside

of a vehicle, a multimeter's positive lead may be connected
to the WHITE  wire  however  the  BROWN  wire  must  be
connected to BOTH the  multimeter's  negative  lead  AND
power ground going to the X-Series device.  This connection
is usually made by the circuitry inside an ECU or data
logger.

0-5V Analog Output Scaling Table

Volts

psig

bar

<0.50

SENSOR ERROR

0.50

0.0

0.0

0.75

0.9

0.1

1.00

1.9

0.1

1.25

2.8

0.2

1.50

3.8

0.3

1.75

4.7

0.3

2.00

5.6

0.4

2.25

6.6

0.5

2.50

7.5

0.5

2.75

8.4

0.6

3.00

9.4

0.6

3.25

10.3

0.7

3.50

11.3

0.8

3.75

12.2

0.8

4.00

13.1

0.9

4.25

14.1

1.0

4.50

15.0

1.0

>4.50

SENSOR ERROR

Содержание 30-0309

Страница 1: ...real time A 0 5V analog and an AEMnet CAN bus output is included and can be used with data loggers or aftermarket ECUs including the AEM Infinity Engine Management System EMS Features 2 1 16 52mm out...

Страница 2: ...l extras use JST P N SPUD 001T P0 5 terminals for 22 26 AWGwire Connector A Power IO Pin Color Description 1 RED Switched 12V Power 5A Fuse 2 BLACK Power Ground 3 GREEN BLACK AEMnet CANL 4 WHITE BLACK...

Страница 3: ...reshold value The gauge will return to normal display mode a few seconds after the last button press Display or clear stored peak value Press the PEAK button the peak highest sensor reading will be di...

Страница 4: ...ronics com for more information The faceplate may be reversible displaying alternative scalings on either side Reference the Operation section of this manual for details on how to switch the display m...

Страница 5: ...kit the silver bezel may be replaced for the existing bezel at this time STEP 2 Separate the PCB 11 from the remaining components STEP 3 Slide the light guide 5 upward to remove it the buttons may fa...

Страница 6: ...e up and slide the buttons 6 into the slots STEP 2 Stack the diffuser 4 faceplate 3 and lens 1 in order over the buttons and on to the light guide STEP 3 Reassemble the PCB and display stack with the...

Страница 7: ...suitable for output to devices such as loggers or ECUs This differential output requires special care to ensure proper operation The WHITE signal wire should be connected to the positive of the analog...

Страница 8: ...29 bit ID transmit rate 20 hz terminating resistor none endianness big Motorola DLC 8 Message ID 0x000A0309 Byte Bit Bitmask Label Data Type Scaling Offset Range 0 Pressure 16 bit unsigned 0 01 psig b...

Страница 9: ...repaid and accompanied w ith dated proof of purchase This w arranty applies only to the original purchaser of product and is non transferable All implied w arranties shall be limited in duration to th...

Отзывы: