Caution: 

1. The range of the voltage test must be lower than 250V 

and the function switch must be set to “Vdc” position; 

otherwise the fuse may be damaged.   

2. An AC line voltage is converted into a DC voltage by the 

CZ20252 internal transformer. 

Telecom Line Continuity test 

To check for continuity on the telecommunication line, you can do 

so by the following steps: 

1.  Connect the two sides of the telecom line onto the 

crocodile clips on the lead plugs. 

 

2.  Set the function switch to “M” position. 

3.  Press Vdc button. 

If the CABLE led illuminates, it means there is a good continuity 

on the telecommunication line. If the CABLE LED does not 

illuminate it indicates the telecommunication line does not have a 

good continuity.   

 

Operating in Monitor Mode   

The M (monitor) position  provides a high impedance coupling to allow 

line monitoring without disrupting conversations or signalling.  Set the 

function switch to “M” position and then press the SPKR button to listen 

onto the telecommunication line through the test telephone’s speaker. If 

there is an audible signal on the telecommunication line the signal will 

be amplified through the speaker. If there is no audible signal on the line, 

circuit noise will be amplified through the speaker.  In  monitor  mode 

ensure the circuit connect test  feature  is turned  off.  Otherwise  this  will 

introduce some telecom line crosstalk and result in low sound.

 

 

Operating in Talk Mode

 

The ‘T’ (Talk) position provides an off hook connection for dialling and 

talking as a common telephone.

 

Audio Controls Keys 

The audio control keys (VOL + / SPKR / VOL -) let the operator switch 

Содержание CZ20252

Страница 1: ...CZ20252 User Guide CZ20252 ART01 01 IP54...

Страница 2: ...r will cause the risk of electric shock or product damage You must ensure the telecommunication line the CZ20252 is being connected to is suitable and free from hazardous voltages before using the CZ2...

Страница 3: ...y testing Features 1 IEC EN 60529 IP54 2 Rugged construction for drop and knock proofing 3 Speakerphone for convenient two way hands free conversation 4 High impedance monitor mode DSL safe 5 Direct d...

Страница 4: ...2 Keypad 3 Talk Monitor VDC switch 4 Battery Compartment 9V battery 5 Fuse in battery compartment 6 Speakerphone Monitor amplified speaker 7 Line cord strain relief 8 Optional Belt Hook location 2 pla...

Страница 5: ...sts the voltage of the line 5 CABLE LED Tests the telecommunication line s continuity On a well connected line the CABLE LED illuminates red 6 Vdc LEDs Voltage line level indicators 7 PSE Button PBX p...

Страница 6: ...nfirmed to be safe for a test connection always use Monitor mode to listen for any active services before switching to Talk mode to prevent disconnecting an active service Operating the CZ20252 in Vdc...

Страница 7: ...nication line does not have a good continuity Operating in Monitor Mode The M monitor position provides a high impedance coupling to allow line monitoring without disrupting conversations or signallin...

Страница 8: ...utton again will switch back to tone dialling Speed Dialling Numbers Storing The STO button is used to store numbers in memory There are 12 memory locations keys 0 through 9 and with each capable of s...

Страница 9: ...ssary to insert a pause between digits of a stored number such as when accessing a trunk through a PABX that requires a 9 to get an external line To store a number with a pause simply press the PSE bu...

Страница 10: ...ition when storing Ensure the Mute LED is not illuminated when storing as the battery will be drained by the LED Ensure the Mute button is off before storing the CZ20252 to avoid unnecessary battery d...

Страница 11: ...elecommunications line Speakerphone doesn t work MUTE function is on Check MUTE LED indicator Press the MUTE button and check if the MUTE LED is off Short rings only 1 Low battery 2 The test phone is...

Страница 12: ...on a flat work surface with the battery cover up 2 Use a screwdriver to remove the four screws from the battery compartment 3 Remove the battery cover 4 Remove the old battery and properly discard 5 I...

Страница 13: ...same specification 5xL20mm 250mA 250V of fuse 6 Place the battery and battery cover back then fasten the four screws securely Maintenance 1 Disconnect clips from any metallic connections before perfo...

Страница 14: ...Digit capacity 16 digits per memory PBX pause duration 4 seconds Line Voltage Test AC DC voltage indication under24 V 24 100V 101 150V 151 200V 200V Monitor amplifier power source 9V providing 25 hour...

Страница 15: ...AEGIS CZ20252 User Guide 14 www aegis net au...

Страница 16: ...AEGIS CZ20252 User Guide www aegis net au 15 Aegis Proprietary Limited www aegis net au sales aegis net au...

Отзывы: