![AEG WKL 1003 F Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/aeg/wkl-1003-f/wkl-1003-f_operation-and-installation_11279020.webp)
20
Operation
7. Safety
Only qualified contractors should carry out the maintenance and repair of this appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only if the original accessories and spare parts intended
for the appliance are used.
DANGER Electrocution
If you mount the appliance on the wall, do so in such a way that control equipment cannot be touched by a person in
the bath or shower.
!
CAUTION
—
Only fit the wall mounted appliance to a vertical wall that is temperature-resistant to at least 85 °C.
—
Observe the minimum clearances to adjacent object surfaces.
—
Never install the appliance directly below a wall socket.
—
Ensure that the power cable is not in contact with any appliance components.
7.2 Instructions, standards and regulations
Observe all applicable national and regional regulations and instructions.
Observe the Building and Garage Regulations [or local regulations].
8. Appliance description
8.1 Standard delivery
º Wall mounting bracket (hooked into the appliance)
º Feet
º One-way Screws
9. Installation
9.1 Minimum clearances
≥
20
≥100
≥500
≥100
≥100
≥250
D
00000
19
28
3
INSTALLATION
1
1
2
26
_0
7_
31
_0
03
8
1 Pin
2 Temperature selector
»
To limit the temperature setting range, set the minimum and maximum values at the temperature selector, and push
a pin for each into the slightly offset hole opposite (see diagram).
26
_0
7_
31
_0
17
1
1
1
2
1
Pin
2
Temperature selector
4.4 Shutting down
»
Move the switch on the right of the appliance to OFF.
5. Cleaning, care and maintenance
If a pale brownish discolouration appears on the appliance casing, wipe this off as soon as possible with a damp cloth.
Clean the appliance when cold with ordinary cleaning products. Avoid abrasive or corrosive cleaning products.
CAUTION Fire
Never spray cleaning spray into the air slot.
Ensure that no moisture can enter the appliance.
As part of regular maintenance, we recommend also having the control components checked. The safety and control
components should be checked by a contractor no more than ten years after commissioning.
6. What to do if ...
... the appliance does not heat up:
Check the temperature set at the appliance and the MCB/fuse in your fuse box.
The appliance has a safety temperature controller that shuts the appliance down if it overheats. After the cause has been
removed (for example air outlet or inlet apertures covered) and the appliance has cooled down for a few minutes, ope-
ration starts again.
If you cannot remedy the fault, contact your contractor. To facilitate and speed up your enquiry, please provide the number
on the type plate (no. XXXXXX - XXXX - XXXXXX):
289635-38533-1509_WKL_503-3003-F_de_en_fr_nl_pl_cs_ru.indb 20
17.02.2015 14:55:35