Problem
Possible cause
Remedy
The tumble dry‐
er does not heat
up. The laundry
inside is cold
and wet.
The filter is clogged. The emergen‐
cy heater shutdown.
Clean the filter.
1)
Display shows 1
min or few mi‐
nutes to the cy‐
cle end for lon‐
ger time. The
laundry inside is
cold and wet.
The filter is clogged. The emergen‐
cy heater shutdown.
Clean the filter.
1)
Unsatisfactory
drying result.
Incorrect program selection.
Select a suitable program.
2)
The filter is clogged.
Clean the filter.
1)
Dryness Level option was set to
iron dry.
3)
Change Dryness Level option to a
higher level.
The load was too large.
Do not exceed the maximum load
size.
The airflow slots are clogged.
Clean the airflow slots at the bot‐
tom of the appliance.
There is some dirt on the humidity
sensor in the drum.
Clean the front surface of the
drum.
The dryness level was not set to
the desired level.
Adjust the dryness level.
4)
The condenser is clogged.
Clean the condenser.
1)
The loading
door does not
close
The filter is not locked into posi‐
tion.
Put the filter in the correct position.
Laundry is trapped between the
door and the seal.
Remove trapped items and close
the door.
It is not possible
to change the
program or op‐
tion.
After a cycle starts it is not possi‐
ble to change the program or op‐
tion.
Turn the tumble dryer off and on.
Change the program or option as
required.
It is not possible
to select an op‐
tion. An acoustic
signal is emit‐
ted.
The option you tried to select is not
available for the selected program.
Turn the tumble dryer off and on.
Change the program or option as
required.
ENGLISH
21
Содержание T6DBG821N
Страница 1: ...USER MANUAL EN User Manual Tumble Dryer T6DBG821N T6DBG822N ...
Страница 26: ......
Страница 27: ......
Страница 28: ...www aeg com shop 136947504 A 112023 ...