2

Functional buttons  ON/OFF 

Front-EPO

System status LEDs

 

 

• Normal

• Battery

• Bypass

• Error

Power outages can 

lead to significant 

financial loss

Almost all labor and 

production processes today 

are based on high capacity 

data and IT infrastructure. 

Power outages or voltage 

fluctuations that lead to 

systems failure end almost 

always with disrupted 

operations, loss of production 

and, at worst, irretrievable data 

loss.

Your important IT infrastructure 

must be permanently available 

and protected against power 

disturbances of all kinds. 

Through the use of VFI 

(conversion) technology, 

Protect 3.M 2.0 reliably protects 

your systems against power 

outages and network 

disruptions and ensures the 

value of your business.

Modularity provides 

safety reserves and 

flexibility

Protect 3.M 2.0 is an 

uninterruptible power supply 

of the highest reliability.

With increasing demands on 

performance, the compact 

modular design adapts 

the permitted UPS power 

according to your current 

power needs. This can be done 

without additional installation 

costs since the power modules 

can be easily inserted and are 

automatically recognized by 

the system (“hot swappable”). 

No additional connections are 

required for this operation.

Dynamic redundancy

An automatic load balancing 

to all modules within an 

appropriately designed system 

delivers N+x redundancy 

without the requirement for 

any configuration changes or 

increases to load capacity.

High efficiency lowers 

operating costs and 

CO

2

 emissions

Protect 3.M 2.0 is based 

on high efficiency IGBT 

technology. This provides 

an efficiency of up to 95 % 

in double conversion mode. 

With a 35 % loading, the UPS 

still maintains an efficiency 

of 94 %. In addition to the 

lowering of power loss 

unwanted generation of 

heat is also reduced, thereby 

reducing air conditioning 

requirements. All of this leads 

to significant cost savings and 

a reduction in CO

2

 emissions.

Input power factor 1.0

100 % active power from the 

UPS reduces the generator 

specification and consequent 

installation cost increases.

Protect 3.M 2.0

Содержание Protect 3.M 2.0

Страница 1: ...The flexible redundancy concept ensures a steady power supply to any connected devices Lower operating costs for energy and cooling with high efficiency and fast module replacement in the event of power failure reduce operational costs and ensure an optimal price vs performance ratio for the Protect 3 M 2 0 UPS solution Key features Modular design allows for flexible adaption to the current power ...

Страница 2: ...pts the permitted UPS power according to your current power needs This can be done without additional installation costs since the power modules can be easily inserted and are automatically recognized by the system hot swappable No additional connections are required for this operation Dynamic redundancy An automatic load balancing to all modules within an appropriately designed system delivers N ...

Страница 3: ...d current Admissible power factor 0 1 inductive to 0 1 capacitive Battery Rated voltage 240 V DC Max charging power 5 A 10 A 15 A 20 A 25 A 30 A Charging principle Load switching per power module Autonomy time Selectable over external battery cabinet Static bypass Nominal voltage 3 x 400 V 380 415 V adjustable 3 phase neutral Frequency 50 Hz 60 Hz adjustable Synchronization range 0 1 5 adjustable ...

Страница 4: ...ignal contacts MODBUS extension card and SNMP adapter Battery Management Each UPS power module contains its own battery charger with intelligent charging electronics These can be adapted to the battery in use and facilitate the use of vendor independent standard batteries A temperature compensated charging curve ensures an optimum charging regime Automatic testing informs you of the charging state...

Отзывы: