background image

11

English

mAINTENANCE

NOTE:

  Used  oil  should  be  disposed  of  at  an  approved 

disposal site. See your local oil retailer for more information.

CLEANING FUEL SEDIMENT CUP

The sediment cup prevents dirt and water that may have gotten 

into the fuel tank from entering the carburetor. If the engine 

has not been run for a long time, the sediment cup should be 

cleaned before use.

n

 

Turn the fuel valve to the OFF position.

n

 

Remove the sediment cup using a 10 mm wrench (not 

provided).

n

 

Remove the O-ring and filter.

n

 

Clean  each  of  the  parts  in  carburetor  cleaner  or  any 

comparable cleaning product.

n

 

Reinstall  the  filter,  O-ring,  and  sediment  cup.  Tighten 

with wrench to secure.

n

 

Return the fuel valve to ON position and check for leaks.

CLEANING THE EXHAUST PORT AND MUFFLER

Depending on the type of fuel used, the type and amount of 

oil used, and/or your operating conditions, the exhaust port 

and  muffler  may  become  blocked  with  carbon  deposits.  If 

you notice a power loss with your petrol-powered tool, you 

may need to remove these deposits to restore performance. 

We highly recommend that only qualified service technicians 

perform this service.

DRAINING FUEL TANK

When not using a fuel stabiliser, draining the fuel from the 

tank before storage may help prevent gum deposits in the 

fuel system.

n

 

Turn the engine switch OFF ( O ).

n

 

Close fuel valve.

n

 

Remove the fuel line from the petcock by squeezing the 

ends of the retaining clip and sliding the fuel line off.

n

 

Install  one  end  of  a  drain  line  over  the  petcock,  and 

place the other end in a fuel container large enough to 

catch the fuel being drained from the tank.

n

 

Open fuel valve.

n

 

When the fuel has drained from the tank, close the fuel 

valve and reinstall fuel line on petcock.

TRANSPORTING

n

 

Turn engine switch OFF ( O ).

n

 

Close the fuel valve.

n

 

Make sure engine and exhaust of unit is cool.

n

 

Keep unit level to prevent fuel spillage. 

n

 

Do not drop or strike unit or place under heavy objects.

Содержание Powertools AGN5000DEB

Страница 1: ...Original Instructions AGN5000DEB DIESEL PORTABLE GENERATOR ...

Страница 2: ...1 Fig 2 Fig 4 recoil starter grip oil CAP Dipstick FUEL CAP FUEL LEVEL GAUGE oil drainage bolt FUEL TANK recoil starter grip oil cap dipstick oil fill hole fuel level gauge fuel tank fuel cap Fig 3 fuel cap ...

Страница 3: ...Fig 6 Fig 5 Fig 8 IGNITION KEY ALTERNATOR END COVER Air filter cover filter elements air filter cover fuel cock Air filter Fig 7 ...

Страница 4: ...ON OFF Fig 9 Fig 10 ON OFF ON OFF fuel line fuel cock petcock fuel cock o ring filter sediment cup ...

Страница 5: ... hearing protection when operating this equipment n Keep all bystanders children and pets at least 3 metres away n Wear sturdy and dry shoes or boots Do not operate while barefoot n Do not operate generator when you are tired or under the influence of drugs alcohol or medication n Keep all parts of your body away from any moving parts and all hot surfaces of the unit n Product users in some states...

Страница 6: ...eep the generator a minimum of 1 metre away from all types of combustible material n Do not operate generator near hazardous material n Do not operate generator at a diesel filling station n Do not touch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury n Do not connect to a building s electrical system unless a transfer switch has been properly instal...

Страница 7: ...k Toxic Fumes Running generator gives off carbon monoxide an odorless colorless poison diesel Breathing carbon monoxide can cause nausea fainting or death Fire Explosion Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of...

Страница 8: ...ing thrown into your eyes which can result in severe eye damage Before beginning power tool operation always wear safety goggles or safety glasses with side shields and when needed a full face shield We recommend Wide Vision Safety Mask for use over eyeglasses or standard safety glasses with side shields Always wear eye protection SAVE THESE INSTRUCTIONS The following signal words and meanings are...

Страница 9: ... 38 m 20 m 40 9200 27 m electric motor loads It is characteristic of common electric motors in normal operation to draw up to six times their running current while starting This table may be used to estimate the watts required to start Code G electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Alway...

Страница 10: ...arting watts you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Tool or Appliance Continuous Running Watts...

Страница 11: ...f fuel level gauge Consult the fuel level gauge to determine the amount of fuel remaining in the generator fuel tank The fuel tank capacity is 11 5L for diesel generator fuel valve The flow of fuel through the generator is controlled by the position of the fuel valve ground terminal The ground terminal is used to assist in properly grounding the generator to help protect against electrical shock C...

Страница 12: ...e damaged or missing please contact your nearest authorised service centre for assistance PACKING LIST Generator Supply kit Operator s Manual WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Failure to heed this warning could result in serious personal injury WARNING Do not attempt to modify this tool or create accessories not recommended for use...

Страница 13: ...e fuel cap n Fill the fuel tank to 25 mm below the top of the fuel neck n Replace and secure the fuel cap NOTE Always use 0 diesel Never use old stale or contaminated diesel and do not use an oil diesel mixture Do not allow dirt or water into the fuel tank CAUTION On a level surface with the engine off check the oil level before each use of the generator AC OPERATION n Unplug all loads from the ge...

Страница 14: ... use only identical RYOBI replacement parts Use of any other parts may create a hazard or cause product damage Only the parts shown on the parts list are intended to be repaired or replaced by the customer All other parts should be replaced at an authorised service centre GENERAL MAINTENANCE Keep the generator in a clean and dry environment where it is not exposed to dust dirt moisture or corrosiv...

Страница 15: ...haust port and muffler may become blocked with carbon deposits If you notice a power loss with your petrol powered tool you may need to remove these deposits to restore performance We highly recommend that only qualified service technicians perform this service draining fuel tank When not using a fuel stabiliser draining the fuel from the tank before storage may help prevent gum deposits in the fu...

Страница 16: ...k fuel pipe Replace if necessary Adjust valve clearance for intake and exhaust valves 1st time Check the level of battery electrolyte Monthly MAINTENANCE MAINTENANCE SCHEDULE The chart above indicates what checks to make and when to make them The mark indicates special tools and skills are required Please consult with our dealers for assistance These items should only be carried out by an authoriz...

Страница 17: ...e of start The fuel nozzle is dirty Clean the fuel nozzle Circuit breaker is not closed Put the circuit breaker to ON position The connection of socket is not good Adjust the feet of socket The rated speed of generator can not be reached Adjust it according to the requirements Carbon brush worn Change the carbon brush AVR worn Change the AVR Low current while welding Check all the connections Chec...

Страница 18: ...14 English WIRING DIAGRAM AGN5000DEB ...

Страница 19: ......

Страница 20: ...zed reseller or if product is sold AS IS and or WITH ALL FAULTS Where permitted the provisions of this limited warranty are in lieu of any other written warranty whether express or implied written or oral including any warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL WE BE LIABLE FOR SPECIAL INCIDENTAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OUR MAXIMUM LIABILITY SHALL...

Страница 21: ... 34 0 91 627 93 29 TECHTRONIC INDUSTRIES ASIA CO LTD 24 F CDW Building 388 Castle Peak Road Tsuen Wan Hong Kong Tel 852 2402 6888 RYOBI TECHNOLOGIES GMBH Itterpark 4 D 40724 Hilden DEUTSCHLAND Tel 49 0 2103 2958 0 Fax 49 0 2103 2958 29 RYOBI TECHNOLOGIES GMBH Vertriebsbüro Österreich Schinitzgasse 13 A 8605 Kapfenberg Tel 43 0 3862 23590 0 Fax 43 0 3862 23590 25 TECHTRONIC INDUSTRIES AUSTRALIA PTY...

Страница 22: ......

Отзывы: