background image

8

English

RECEPTACLES

Your generator has the following single phase, 50 Hz outlets: 

two 230 Volt AC, 16 Amp receptacle. These can be used for 

operating  appropriate  appliances,  electrical  lighting,  tools, 

and motor loads.

RECOIL STARTER GRIP

The recoil starter grip is used (along with the engine speed 

lever) to start the generator’s engine. 

DC TERMINALS

The DC terminals may ONLY be used for charging 12 volt 

automotive type batteries. 
The terminals are colored red to identify the positive (+)terminal 

and black to identify the negative (-) terminal. The battery must 

be connected to the generator DC terminals with the proper 

polarity (battery positive to generator red terminal and battery 

negative to the generator black terminal).

DC CIRCUIT PROTECTOR

The  DC  circuit  protector  automatically  shuts  off  the  DC 

battery  charging  circuit  when  the  DC  charging  circuit  is 

overloaded,  when  there  is  a  problem  with  the  battery,  or 

when the connections between the battery and the generator 

are improper.

COMPRESSION RELIEF VALVE

BATTERY

12V, 20AH battery is used for electric starting.

IGNITION KEY

AssEmBLy

UNPACKING

This product has been shipped completely assembled.

n

  Remove one end of the box and carefully slide out the 

generator and any accessories. 

 

NOTE: 

The generator is heavy. If you must lift the unit 

out of the box, get another person to help you and lift with 

your legs, not your back.

n

  Inspect the unit carefully to make sure no damage occurred 

during shipping.

n

  Do not discard the packing material until you have  carefully 

inspected and satisfactorily operated the  product.

n

   If any parts are damaged or missing, please contact your 

nearest authorised service centre for assistance.

PACKING LIST

Generator 

Supply kit

Operator’s Manual

 

WARNING: 

 

If any parts are damaged or missing do not operate 

this product until the parts are replaced. Failure to 
heed  this  warning  could  result  in  serious  personal 
injury.

 

WARNING: 

 

Do  not  attempt  to  modify  this  tool  or  create 

accessories  not  recommended  for  use  with  this 
tool.  Any  such  alteration  or  modification  is  misuse 
and  could  result  in  a  hazardous  condition  leading 
to possible serious personal injury.

OpERATION

  DANGER:

 

Carbon monoxide.

 Using a generator indoors WILL 

KILL YOU IN MINUTES.

Generator exhaust contains high levels of carbon monoxide 
(CO), a poisonous diesel you cannot see or smell. If you can 
smell the generator exhaust, you are breathing CO. But even 
if you cannot smell the exhaust, you could be breathing CO.

n

 

Never  use  a  generator  inside  homes,  garages, 

crawlspaces,  or  other  partly  enclosed  areas.  Deadly 
levels of carbon monoxide can build up in these areas. 
Using  a  fan  or  opening  windows  and  doors  does  NOT 
supply enough fresh air.

n

 

ONLY use a generator outdoors and far away from open 

windows, doors, and vents. These openings can pull in 
generator exhaust.

Even when you use a generator correctly, CO may leak into 
the home. ALWAYS use a battery-powered or battery-backup 
CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has 
been running, move to fresh air RIGHT AWAY. See a doctor. 
You could have carbon monoxide poisoning.

  DANGER: 

 

Failure  to  properly  ground  generator  can  result 

in  electrocution,  especially  if  the  generator  is 
equipped  with  a  wheel  kit.  Generators  have  to  be 
properly  grounded  to  an  approved  earth  ground. 
Call an electrician for local grounding requirements. 

FEATURES

Содержание Powertools AGN5000DEB

Страница 1: ...Original Instructions AGN5000DEB DIESEL PORTABLE GENERATOR ...

Страница 2: ...1 Fig 2 Fig 4 recoil starter grip oil CAP Dipstick FUEL CAP FUEL LEVEL GAUGE oil drainage bolt FUEL TANK recoil starter grip oil cap dipstick oil fill hole fuel level gauge fuel tank fuel cap Fig 3 fuel cap ...

Страница 3: ...Fig 6 Fig 5 Fig 8 IGNITION KEY ALTERNATOR END COVER Air filter cover filter elements air filter cover fuel cock Air filter Fig 7 ...

Страница 4: ...ON OFF Fig 9 Fig 10 ON OFF ON OFF fuel line fuel cock petcock fuel cock o ring filter sediment cup ...

Страница 5: ... hearing protection when operating this equipment n Keep all bystanders children and pets at least 3 metres away n Wear sturdy and dry shoes or boots Do not operate while barefoot n Do not operate generator when you are tired or under the influence of drugs alcohol or medication n Keep all parts of your body away from any moving parts and all hot surfaces of the unit n Product users in some states...

Страница 6: ...eep the generator a minimum of 1 metre away from all types of combustible material n Do not operate generator near hazardous material n Do not operate generator at a diesel filling station n Do not touch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury n Do not connect to a building s electrical system unless a transfer switch has been properly instal...

Страница 7: ...k Toxic Fumes Running generator gives off carbon monoxide an odorless colorless poison diesel Breathing carbon monoxide can cause nausea fainting or death Fire Explosion Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of...

Страница 8: ...ing thrown into your eyes which can result in severe eye damage Before beginning power tool operation always wear safety goggles or safety glasses with side shields and when needed a full face shield We recommend Wide Vision Safety Mask for use over eyeglasses or standard safety glasses with side shields Always wear eye protection SAVE THESE INSTRUCTIONS The following signal words and meanings are...

Страница 9: ... 38 m 20 m 40 9200 27 m electric motor loads It is characteristic of common electric motors in normal operation to draw up to six times their running current while starting This table may be used to estimate the watts required to start Code G electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Alway...

Страница 10: ...arting watts you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Tool or Appliance Continuous Running Watts...

Страница 11: ...f fuel level gauge Consult the fuel level gauge to determine the amount of fuel remaining in the generator fuel tank The fuel tank capacity is 11 5L for diesel generator fuel valve The flow of fuel through the generator is controlled by the position of the fuel valve ground terminal The ground terminal is used to assist in properly grounding the generator to help protect against electrical shock C...

Страница 12: ...e damaged or missing please contact your nearest authorised service centre for assistance PACKING LIST Generator Supply kit Operator s Manual WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Failure to heed this warning could result in serious personal injury WARNING Do not attempt to modify this tool or create accessories not recommended for use...

Страница 13: ...e fuel cap n Fill the fuel tank to 25 mm below the top of the fuel neck n Replace and secure the fuel cap NOTE Always use 0 diesel Never use old stale or contaminated diesel and do not use an oil diesel mixture Do not allow dirt or water into the fuel tank CAUTION On a level surface with the engine off check the oil level before each use of the generator AC OPERATION n Unplug all loads from the ge...

Страница 14: ... use only identical RYOBI replacement parts Use of any other parts may create a hazard or cause product damage Only the parts shown on the parts list are intended to be repaired or replaced by the customer All other parts should be replaced at an authorised service centre GENERAL MAINTENANCE Keep the generator in a clean and dry environment where it is not exposed to dust dirt moisture or corrosiv...

Страница 15: ...haust port and muffler may become blocked with carbon deposits If you notice a power loss with your petrol powered tool you may need to remove these deposits to restore performance We highly recommend that only qualified service technicians perform this service draining fuel tank When not using a fuel stabiliser draining the fuel from the tank before storage may help prevent gum deposits in the fu...

Страница 16: ...k fuel pipe Replace if necessary Adjust valve clearance for intake and exhaust valves 1st time Check the level of battery electrolyte Monthly MAINTENANCE MAINTENANCE SCHEDULE The chart above indicates what checks to make and when to make them The mark indicates special tools and skills are required Please consult with our dealers for assistance These items should only be carried out by an authoriz...

Страница 17: ...e of start The fuel nozzle is dirty Clean the fuel nozzle Circuit breaker is not closed Put the circuit breaker to ON position The connection of socket is not good Adjust the feet of socket The rated speed of generator can not be reached Adjust it according to the requirements Carbon brush worn Change the carbon brush AVR worn Change the AVR Low current while welding Check all the connections Chec...

Страница 18: ...14 English WIRING DIAGRAM AGN5000DEB ...

Страница 19: ......

Страница 20: ...zed reseller or if product is sold AS IS and or WITH ALL FAULTS Where permitted the provisions of this limited warranty are in lieu of any other written warranty whether express or implied written or oral including any warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL WE BE LIABLE FOR SPECIAL INCIDENTAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OUR MAXIMUM LIABILITY SHALL...

Страница 21: ... 34 0 91 627 93 29 TECHTRONIC INDUSTRIES ASIA CO LTD 24 F CDW Building 388 Castle Peak Road Tsuen Wan Hong Kong Tel 852 2402 6888 RYOBI TECHNOLOGIES GMBH Itterpark 4 D 40724 Hilden DEUTSCHLAND Tel 49 0 2103 2958 0 Fax 49 0 2103 2958 29 RYOBI TECHNOLOGIES GMBH Vertriebsbüro Österreich Schinitzgasse 13 A 8605 Kapfenberg Tel 43 0 3862 23590 0 Fax 43 0 3862 23590 25 TECHTRONIC INDUSTRIES AUSTRALIA PTY...

Страница 22: ......

Отзывы: