GB
37
ChargiNg phases
the concept of the charging process is explained based on a 12 V battery.
Diagnosis
diagnostic function which automatically checks the battery status and recognises the
voltage.
Voltage
Function
0 V to 1.5 V
“error” Led (9) lit. Battery defective.
1.5 V to 12 V
Charging starts.
12 V to 13 V
Maintenance charging starts.
14.6 V
Battery fully charged. “Full” Led (10) lit.
>15 V
“error” Led (9) lit.
Step 1: Condition check
the charger checks the battery condition and calculates the required
charging parameters.
Step 2: Desulphation (rescue)
▪
the charger can rescue most drained batteries with voltages up to a minimum of
1.5
±
0.5 V.
▪
the safety switch does not allow the charger to start charging if the voltage is
below 1.5
±
0.5 V.