Level of protection against ingress of solid particles
and moisture ensured by the protective cover, ex‐
cept where the low voltage equipment has no pro‐
tection against moisture
IPX4
Water supply
1)
Cold water
Water supply pressure
2)
Minimum
Maximum
0.5 bar (0.05 MPa)
8 bar (0.8 MPa)
Maximum wash load
Cotton
7 kg
Maximum dry load
Cotton
Synthetics
4 kg
3 kg
Spin Speed
Maximum spin speed
1551 rpm
1) Connect the water inlet hose to a water tap with a 3/4'' thread.
2) The appliance works correctly if the water pressure is not lower than 0.05 MPa (0.5 bar). If you cannot
connect the water inlet hose to the cold water tap of the primary hydraulic system, connect it to your do‐
mestic cold water storage system. Make sure not to exceed a distance of 5.02 m (16.5 ft) between the
appliance inlet hose and the bottom of the water storage tank.
5. INSTALLATION
WARNING!
Refer to Safety chapters.
5.1 Be prepared for
installation
It is recommended that
installation is carried out by
two persons.
5.2 The appliance is equipped
with ...