• The appliance must not be connected with an extension cable, an adapter or a multiple
connection (risk of fire). Check that the ground connection is in conformity with the
standard and regulations force.
• Connect the appliance to the mains with a device that lets to disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm, eg. auto
-
matic line protecting cut-out, earth leakage trips or fuse.
• None of a parts of the connection cable can not get a temperature 90°C. The blue neu
-
tral cable must be connected to the terminal block label with "N". The brown (or black)
phase cable (fitted in the terminal block contact marked with "L") must always be con
-
nected to the live phase.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90 or equivalent type. Make sure that
the cable section is applicable to the voltage and the working temperature. The yellow/
green earth wire must be approximately 2 cm longer than the brown (or black) phase wire.
Building In
min. 55 mm
min. 650 mm
560 mm
min. 100 mm
30 mm
480 mm
600 mm
10 mm
11 mm
11 mm
A
3 mm
A
-
supplied
seal
A
B
A - supplied seal
B - supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to remove and let an easy access in case a
technical assistance intervention is necessary.
Installation
19
Содержание HK614000H
Страница 50: ...50 ...
Страница 51: ...51 ...
Страница 52: ...www aeg com shop 397132901 B 192011 ...