Assembling the juice extractor

Before first use, the appliance parts 
should be cleaned (section on “Dis-
mantling and cleaning”).

0

Place the appliance on a flat, dry work 
surface.
Unwanted flex can be inserted into the 
flex compartment (Fig. 1/12).

0

Arrange the motor part in an upright 
position so that the knob at the front 
faces you.

0

Place the juice bowl with the juice out-
let on the LH side of the motor part 
(Fig. 2).

0

Place the strainer basket in the juice 
bowl (Fig. 3).

0

Place the upper part with the juice 
outlet on the LH side (Fig. 4). 

0

Engage and press down the locking 
clips (Fig. 5).

0

Push the residue container in properly, 
so that it engages (Fig. 6).

0

Place the container supplied or anoth-
er suitable vessel underneath the juice 
outlet (Fig. 7).

0

Position the plunger.

Safety system

The appliance can only be switched on, 
if all parts of the appliance are pro-
perly assembled and joined together.

• The juice bowl must be properly 

inserted (Fig. 2).

• The locking clips must be properly 

locked (Fig. 5). 

• The residue container must be properly 

inserted, so that it engages (Fig. 6).

Operate the appliance as follows:

For soft fruit
and vegetables =
Knob to the 

right

For firm fruit
and vegetables =
Knob to the 

left

To switch off the juice extractor, turn 
the knob to “0”.

Juice extraction

Fill the appliance with the prepared, 
chopped fruit or vegetables and lightly 
press down with the plunger. Smaller 
pieces can be shaken down on to the 
surface of the filling bowl. With the 
plunger, move the fruit or vegetables 
towards the filling shaft. When filling 
fruit containing pips (e.g. grapes, to-
matoes), hold the plunger when reple-
nishing so that it always evenly covers 
the filling opening. When re-applying 
the plunger, make sure that the motor 
is not too strongly retarded. Make sure 
that the full residue container is 
promptly emptied. Please check that 
the strainer basket is free from obs-
truction. When the juice has been ex-
tracted from the last piece, the motor 
must run until juice ceases to drip.

Dismantling and cleaning

Important note! The appliance should 
only be dismantled when the motor 
has been switched off and the applian-
ce unplugged.

0

Take out the plunger, remove the resi-
due container.

0

Unclip both locking clips und lift off 
the upper part.

0

The strainer basket and juice bowl are 
removed from the motor base together. 
Wipe the motor part only with a damp 
cloth! Clean all other parts in hot wa-
ter or in normal washing-up water! The 
sooner this happens after appliance 
use, the more easily will cleaning pro-
ceed! Use a brush to clean the strainer 
basket and groove in the upper part. 
Please treat the appliance gently. Never 
scratch or scour it. Any possible discol-
orations (e. g. due to carrots or beet-
root) can be rubbed off with vegetable 
oil.
Do 

not

 

clean

 

in the dishwasher

 the 

motor part, upper housing and plunger. 
Never immerse the appliance in water!

ESF103_neu_de.book  Seite 9  Montag, 15. Dezember 2003  2:46 14

Содержание ESF 103.1

Страница 1: ...ówka Odšt avòovaè Gyümölcsentrifuga Aðï õìùôÞ Gebrauchsanweisung Operating instructions Instrucciones para el uso Instruções de utilização Bruksanwisning Käyttöohje Instrukcja obs ugi Návod k použití Használati útmutató Ïäçãßåò ñÞóçò ESF103_neu_de book Seite 0 Montag 15 Dezember 2003 2 46 14 ...

Страница 2: ...ESF103_neu_de book Seite 1 Montag 15 Dezember 2003 2 46 14 ...

Страница 3: ...2 1 ESF103_neu_de book Seite 2 Montag 15 Dezember 2003 2 46 14 ...

Страница 4: ...3 7 6 5 4 3 2 ESF103_neu_de book Seite 3 Montag 15 Dezember 2003 2 46 14 ...

Страница 5: ... part of the housing Never use the supply lead to pull the plug out of the socket Never immerse the appliance in water Do not use the appliance if the supply cord is damaged the housing or the strainer basket show visible damages Only use the appliance if all parts are properly assembled and joined together Do not remove the upper part while the appliance is in use Only switch the appliance on whe...

Страница 6: ...own with the plunger Smaller pieces can be shaken down on to the surface of the filling bowl With the plunger move the fruit or vegetables towards the filling shaft When filling fruit containing pips e g grapes to matoes hold the plunger when reple nishing so that it always evenly covers the filling opening When re applying the plunger make sure that the motor is not too strongly retarded Make sur...

Страница 7: ...actor Feed everything with soft leaves e g spinach into the juice extractor rolled into a ball Cabbage All of a red or white cabbage can be juiced Either cut the heads into suitably sized pieces or remove the leaves from the stalk and roll them into a ball Vegetable fruits e g Cucumbers melons papaya pomegranates Do not peel or remove skins except for melons cut into suitably sized pieces do not r...

Страница 8: ...itch off the appliance remove the plug from the mains socket When the motor has stopped clean the strainer basket and the ejection hole there is a noticeable unbalance in the appliance The foodstuffs from which the juice is being extracted are not equally distributed It is possible that hard pieces have got caught on the strainer basket Switch off the appliance remove the plug from the mains socke...

Страница 9: ...AEG Hausgeräte GmbH Postfach 1036 D 90327 Nürnberg http www aeg hausgeraete de Copyright by AEG 822 949 274 1203 ESF103_neu_de book Seite 52 Montag 15 Dezember 2003 2 46 14 ...

Отзывы: