SOE/PR
27
599 72 48-93
Press the “Start/Pause” button repeatedly to scroll through the list of the diagnostics mode:
Activations
LCD display
Feature
--
1 ALARM CODE ixx
•
Shows the alarms stored and activation of the
system
1
3 LED TEST
•
Test of all LEDs and the display
•
Cancellation of all alarms stored
2
4 LINE TESTS
Alternates with
NUMBER OF CYCLES
•
Selection of test cycle
•
Count of all cycles carried out
3
5 PULSE WASHING YES
•
Enables/disables pulse washing
4
6 EXTRA RINSE NO
•
Enables/disables the extra rinse
5
BRIGHTNESS 10
•
Brightness setting
6
CONTRAST 6
•
Contrast setting
7
HARDNESS 5
•
Adjustment of the regenerating level depending on
the water hardness
Press the
OK
button to enter a specific Service Option.
Press
Start/Pause
to change the current setting.
Press
OK
to confirm the modification.
To quit diagnostics mode, press button
S0
to turn off the appliance.
8.2
Alarms and activating individual components
1. Enter diagnostics mode
2. Press the
OK
button to display the alarms:
�
The display shows the last alarm that occurred (to decode the alarm, please see the table of
“Alarms”).
3. Press the
OK
button again to display the second alarm that occurred
4. Press the
OK
button once more to display the third alarm that occurred
5. Press the
OK
button repeatedly to scroll through the list of electronic components, as shown in the table
below.
Activations
LCD display
Function enabled
1
1 ERR CODE i 0
c:>
Displays the last alarm that occurred (for example, no alarm)
2
1 ERR CODE i 0
c:>
Displays the last but one alarm that occurred (for example,
no alarm)
3
1 ERR CODE i 0
c:>
Displays the last but two alarm that occurred (for example,
no alarm)
4
2 TEST ACTIVAT. 4
c:>
Regenerating solenoid valve activated
5
2 TEST ACTIVAT. 5
c:>
Drain pump activated
6
2 TEST ACTIVAT. 6
c:>
Fill to water level solenoid valve activated
7
2 TEST ACTIVAT. 7
c:>
Heating element activated
(only with water at full level!)
Содержание EDW1103
Страница 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Страница 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Страница 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Страница 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Страница 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Страница 56: ...SOE PR 56 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Страница 57: ...SOE PR 57 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Страница 58: ...SOE PR 58 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...