Wall unit mounting - Fig. 6
Mark the wall with a centre line, this will aid mounting procedure ,
position the template so that the mid line printed on the template
matches with the centre line previously drawn
(1)
, drill two holes Ø
8mm
(2)
.
Fit two wall plugs with hooks
(3)
.
Hang the hood and adjust its position
(4)
.
Remove the grease filters
(5)
and from the inside of the hood mark 4
points for fixing
(6)
. Remove the hood
and drill 4 holes Ø 8mm.
Fit two wall plugs
(7)
.
Fit the chimney support
(8)
with wall plugs and screws close to the
ceiling, check that the support is perfectly centered.
Hang the hood again and fix securely with 4 screws
(9)
.
Connect a tube to the exit hole of the hood
(10)
long enough to reach
the outside (suction version) or the deflector connection ring (filtering
version).
Make electrical connection
(11)
.
Fix the chimney up
(12a)
to the chimney support
(12b)
.
slide the lower section of the chimney down into the housing on top
of the hood
(13)
.