14
Installation - for contractors
9.2
Wall mounting
note
Observe the dimensions and minimum clearances
in chapter "Specification".
» Drill the holes and insert rawl plugs.
26
_0
7_
80
_00
58
1
4
5
6
3
2
1 Retainer screw
2 Wall sleeve
3 Lock screw
4 Angle shim (BHG 750-1000W) | Washer (BHG 750
C)
5 Retainer
6 Cap
» BHG 750-1000 W: Use screws to secure the wall
sleeves and the shims.
» BHG 750 C: Use screws to secure the wall sleeves
and the washers.
» Secure the retainers to the rungs. Do not yet tighten
the retainers.
26
_0
7_
80
_00
56
» Fit the wall mounting bracket. For this, observe the
slot position. The slot must point respectively up or
down.
D
00000
40
88
2
» Assemble the appliance and wall mounting bracket.
» Insert and tighten the screws to secure the
appliance.
9.3
Fitting the bathrobe hooks
26
_0
7_
80
_00
55
1
3
2
1 Bathrobe hook
2 Washer
3 Bathrobe hook backplate
» Fit the bathrobe hooks as shown.
10. Power supply
wArning electrocution
In wet rooms such as shower rooms and kitchens,
install the flush box at least 25 cm above the floor.
wArning electrocution
Never operate the appliance with an extension cable
or a multiple socket.
!
Material losses
Ensure the appliance can be separated from the
power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
For this,
use contactors, mains isolators, fuses, etc.
Installa
-
tion with a permanent power cable is not permitted.
!
Material losses
Observe the type plate.
The specified voltage must
match the mains voltage.