3.3 Technical data
Technical data of battery module
Electrical characteristics
Model: AS-BBH1-xxx/HV xxx= 10000 15000
Battery type
LFP
Total energy capacity
[kWh] 10
15
Usable energy capacity
[kWh] 9
13.5
Battery capacity
[Ah]
40
40
Voltage range / usable..v.r.
[V]
235.2~294 336~420
Nominal voltage
[V]
268.8
374
Charge current
[A]
294
420
Disharge cut-off voltage
[V]
235.2
360
Charge/Discharge Current
(Nominal)
[A]
20/20
Charge/Discharge Current
(Max)
[A]
40/40
Max. continuous discharge
current
[A]
50
DOD
90%
Cycle life at 25°C
(under standard charge
conditions, charge 0.2°C,
discharge 0.2°C
≥6000
DC disconnect
Contactor
Fuse
Number of expandable
battery units
[pcs]
max. 8
Warranties
For the latest warranties please refer to:
www.aeg-industrialsolar.de
3.4 Operating data
BMS (Battery Management System)
Power consumption (work) [mA] ≤100
Power consumption (sleep) [mA] ≤0.1
Communication
CAN
Monitoring parameters
System voltage, system
current, cell voltage, cell
temperature
Operating conditions
Installation Location
Indoor conditioned
Operating Temperature
[°C]
-10~50
Operating Temperature
(Recommended)
[°C]
15~30
Storage Temperature
[°C]
-30 ~60
Humidity
[%]
5~95
Altitude
[m]
Max. 2000
Cooling
Natural
convection
Reliability and certification
Certificates (cell)
UL1642
Certificates (battery module) IEC62619 / UL1973
Transportation
UN38.3
Ingress rating
IP54
4. INSTALLATION
4.1 Installation tools and materials
Please ensure you have the following items at hand
before beginning the installation of the AEG high
voltage battery: