background image

8

8

Noise Level (4m) LpA dB (A)

82

Noise Level (7m) LpA dB (A)

77

Noise Level LwA dB (A)

102

RCD

Voltage (V)

240

Fault Current Rating (A)

25

Trip Current Rating (mA)

30

Trip Time Rating (s)

0.05

If any of the labels come off the unit or become hard to read, 
contact the authorised service centre for replacement.

FEATURES

KNOW YOUR GENERATOR

See Figure 3.

The safe use of this product requires an understanding of the 
information on the product and in this operator’s manual as 
well as a knowledge of the project you are attempting. Before 
use of this product, familiarise yourself with all  

operating 

features and safety rules.

AC CIRCUIT BREAKER

The circuit breaker is provided to protect the generator against 
electrical overload and can be used to turn the generator’s 
electrical power on or off.

AIR FILTER

The air filter helps to limit the amount of dirt and dust drawn into 
the unit during operation.  

CHOKE LEVER

The choke lever is used when starting the engine. 

ENGINE SWITCH

The engine switch is used in combination with the recoil starter 
grip to start the generator. It is also used to turn the generator 
off.

FUEL TANK

30 litres

FUEL VALVE

The flow of fuel through the generator is controlled by the 
position of the fuel valve.

GROUND TERMINAL

The ground terminal is used to assist in properly grounding 
the generator to help protect against electrical shock. Consult 
with a local electrician for grounding requirements in your area.

OIL LIGHT

The oil light is an indicator for the oil level. When the oil level is 
too low, the oil light will flash in red.

OIL DRAINAGE BOLT

When changing the engine oil, the oil drainage bolt is loosened 
to allow old engine oil to be drained.

OIL CAP/DIPSTICK

Remove the oil fill cap to check and add oil to the generator 
when necessary.

*DUDJH'RRU3

 

875

2350

Hair Dryer

1250

1250

DIY/Job Site

Quartz Halogen Work Light

1000

1000

$LUOHVV6SUD\HUí+3

 

600

1200

Reciprocating Saw

 

960

1400

(OHFWULF'ULOOí+3

 

600

900

&LUFXODU6DZíLQ

1400

2300

0LWUH6DZíLQ

1800

2900

3ODQHU-RLQWHUíLQ

1800

1800

7DEOH6DZ5DGLDO$UP6DZíLQ

2000

3000

$LU&RPS3

1600

4500

*Wattages listed are approximate. Check tool or appliance for actual wattage.

SPECIFICATIONS

Generator

Product Weight (kg)

115

Product dimensions

Width (mm)

800

Length (mm)

800

Height - Length-folded (mm)

700

Height - Length-open (mm)

1350

AC output

AC Frequency (Hz)

50

AC Output Voltage (V)

240

Rated AC Output (W)

5,200

Rated Current (A)

21.67

Circuit Breaker (A)

25

Power Factor

1.0

DC output

Volts

12

Amps

8.3

12V DC Circuit Breaker Circuit (A)

9.2

Engine

Engine Number

Yamaha MZ360

Engine Type

4-Stroke; air-cooled 
OHV; unleaded fuel

Bore x Stroke

85 x 63

Displacement (cc)

357

Starting System

DC Start or Recoil

Fuel Type

Regular unleaded fuel

Lubrication Oil

SAE 10W-30

Engine Oil Volume (l)

1.1

Fuel Tank Capacity (l)

30

Full Load (h)

9

Half Load (h) 

13

Uncertainty dB

2

Содержание AGN6500

Страница 1: ......

Страница 2: ... with foot Lock Nut Lock Nut Flat Washer Frame Frame crossbar Screw 1 in Engine Switch AC Breaker DC Breaker Key Starter Fuel Tank Oil Drainage Bolt Fuel Cap Choke Lever Fuel Valve Oil Light Air Filter Recoil Starter Grip Carburetor Drain Screw Fig 1 Fig 5 Fig 3 Fig 2 Fig 4 ...

Страница 3: ...3 3 Fuel Tank Fuel Cap Extension Cord Oil Cap Dipstick Oil Cap Dipstick Oil Fill Hole Oil Fill Hole 108 mm 4 1 4 in 16 mm 5 8 in 6 mm 1 4 in Fig 7 Fig 6 Fig 10 Fig 11 Fig 8 Fig 9 ...

Страница 4: ...ments Air Filter Cover Bolt Bolt Recoil Starter Grip Twist lock Receptacle Extension Cord Twist lock Plug Choke Lever To Run Choke open To Start Choke closed OFF ON Fuel Valve Fuel Valve Filter Filter Fig 17 Fig 13 Fig 14 Fig 15 Fig 16 Fig 12 ...

Страница 5: ...ose fuel valve and restrain the unit from moving before transporting in a vehicle Ŷ Allow engine to cool for five minutes before refueling Ŷ To reduce the risk of fire and burn injury handle fuel with care It is highly flammable Ŷ Do not smoke while handling fuel Ŷ Store fuel in a container approved for unleaded fuel Ŷ Position the unit on level ground stop engine and allow to cool before refuelin...

Страница 6: ...tand completely the operator s manual If you do not understand the warnings and instructions in the operator s manual do not use this product Call your nearest authorised service centre for assistance WARNING The operation of any products can result in foreign objects being thrown into your eyes which can result in severe eye damage Before beginning power tool operation always wear safety goggles ...

Страница 7: ...l Surge Starting Watts CD Player 100 0 Space Heater 1800 0 Drill 1 2 HP 600 300 Light Bulb 75 0 2575 Total Running Watts 300 Surge Watts Total Continuous Running Watts 2575 Plus Additional Surge Watts 300 Equals Total Generator Output Required to start all items simultaneously 2875 POWER MANAGEMENT To prolong the life of the generator and attached devices it is important to take care when adding e...

Страница 8: ...p protect against electrical shock Consult with a local electrician for grounding requirements in your area OIL LIGHT The oil light is an indicator for the oil level When the oil level is too low the oil light will flash in red OIL DRAINAGE BOLT When changing the engine oil the oil drainage bolt is loosened to allow old engine oil to be drained OIL CAP DIPSTICK Remove the oil fill cap to check and...

Страница 9: ...the following items 2 legs with rubber feet 6 flat washers 6 lock nuts 4 screws 51 mm 2 in 2 screws 25 mm 1 in Ŷ Raise the front end of the generator where the engine is located high enough to gain access to the frame bottom securely position props underneath to support Ŷ Position a leg over the holes on each side of the frame support Ŷ Insert each 51 mm 2 in screw through a flat washer and insert...

Страница 10: ...ty with tools to make you careless Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Do not use any attachments or accessories not recommended by the manufacturer of this product The use of attachments or accessories not recommended can result in serious personal injury APPLICATIONS This generator is designed to supply electrical power for operating comp...

Страница 11: ...nd hold it until the engine has fully stopped The removable control panel has two 240V 15A sockets Use only with RDEC25 accessory cord Do not exceed separation length of 22 9 m 75 ft or a combination of three RDEC25 accessory cords GenSmart MONITORING SYSTEM The GenSmart monitoring system displays wattage voltage hertz and hours To cycle through each display press and release the select reset butt...

Страница 12: ...p dipstick NOTE Used oil should be disposed of at an approved disposal site See your local oil retailer for more information FUEL FILTER The fuel filter prevents dirt and water that may have gotten into the fuel tank from entering the carburetor If the engine has not been run for a long time the fuel filter should be replaced before use Ŷ Drain the fuel tank into suitable container Ŷ Squeeze the e...

Страница 13: ... fuel to drain completely into the container Ŷ Retighten the drain screw NOTE After draining the fuel tank and carburetor start the engine and allow it to run until the unit runs out of fuel Consult hazardous waste management guidelines in your area for the proper way to dispose of used fuel TRANSPORTING Ŷ Turn engine switch OFF O Ŷ Close the fuel valve Ŷ Make sure engine and exhaust of unit is co...

Страница 14: ...ated to extend storage life For recommendations contact your nearest authorised service centre MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours of operation Every 3 months or 50 hours of operation Every 6 months or 100 hours of operation Every year or after 300 hours of operation Check Engine Oil Ŷ Change Engine Oil Ŷ Ŷ Check Air Filter Ŷ Clean Air Filter Ŷ Change Air Filter Ŷ Repl...

Страница 15: ...er is OFF Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging underheavyloadisnotacause for concern However if the knocking or pinging occurs under normal load at a steady engine speed the problem may be with the brand of unleaded fuel being used Switch to a different brand of unlead...

Страница 16: ...ING DIAGRAM 7KLV VLQJOH SKDVH JHQHUDWRU LV WWHG ZLWK D HG 5HVLGXDO XUUHQW HDUWK OHDNDJH HYLFH ZLWK ZLQGLQJ FRQQHFWHG DV VKRZQ LQ WKH following wiring diagram Generator Residual Current Device Outlet Frame A N E ...

Страница 17: ...17 17 WIRING DIAGRAM ...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: