background image

5

5

3

2

1

2

3

Fig. 12

Fig. 10

Fig. 11

1

1 - Pressure relief valve

2 - To close

3 - To release air

1 - Air filter housing

2 - Air filter

3 - Air filter cover

4 - Air hose

1 - Drain valve

2 - Open position

3 - Closed position

2

3

4

1

Содержание AC30100S

Страница 1: ...AC30100S Original instructions ...

Страница 2: ...2 2 Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modifications ...

Страница 3: ... 6 1 2 1 Air filter assembly 1 Front handle 2 Handle slot 3 Bolt 1 Wheel 2 M6 bolt 3 M6 hex nut 1 Air filter assembly x3 2 Pressure relief valve 3 Front handle 4 Power cord 5 AUTO OFF switch 6 Pressure regulator knob 7 Tank pressure gauge 8 Regulator pressure gauge 9 Quick connect coupler 10 Tank 11 Wheel lock x2 12 Front wheel x2 13 Rear wheel x2 14 Rear handle 15 Drain valve 15 ...

Страница 4: ...tting 3 To reduce pressure Turn counterclockwise 4 Pressure relief valve 5 Regulator locking ring 1 Quick connect air fitting 2 NITTO quick coupler 1 Unlock 2 Lock 1 AUTO position 2 OFF position 3 Tank pressuse gauge 4 Regulated pressure gauge 5 To increase pressure turn clockwise 6 Regulator locking ring 2 ...

Страница 5: ... 3 2 1 2 3 Fig 12 Fig 10 Fig 11 1 1 Pressure relief valve 2 To close 3 To release air 1 Air filter housing 2 Air filter 3 Air filter cover 4 Air hose 1 Drain valve 2 Open position 3 Closed position 2 3 4 1 ...

Страница 6: ...ieces of wood on the tool while it is in operation Do not use in dangerous environments Do not use power tools in damp or wet locations or expose to rain Keep the work area well lit Keep children and visitors away All visitors should wear safety glasses and be kept a safe distance from work area Do not let visitors contact tool or extension cord while operating Never use in an explosive atmosphere...

Страница 7: ...e Do not alter or modify the unit from the original design or function Always be aware that misuse and improper handling of this product can cause injury to yourself and others Never leave a tool unattended with the air hose attached Never point any air tool toward yourself or others Do not operate this air compressor if it does not contain a legible warning label Do not continue to use a tool or ...

Страница 8: ...he product and any accessories from the box WARNING Do not use this product if any parts on the packing list are already assembled to your product when you unpack it Parts on this list are not assembled to the product by the manufacturer and require customer installation Use of a product that may have been improperly assembled could result in serious personal injury Inspect the product carefully t...

Страница 9: ...uick coupler always firmly hold release end of hose 4 Pull back on the release sleeve on the 6 35 mm 1 4 in quick coupler 5 With a firm grip pull out the quick connect air fitting that is attached to the quick coupler TURNING THE AIR COMPRESSOR ON OFF See figure 9 1 With the air compressor plugged in pull the power switch to the AUTO position to power the compressor on 2 To turn the air compressor...

Страница 10: ... the tool or release the pressure from the tank by the drain valve 4 Drain water from the tank as instructed in Draining the Tank section Leave the valve open until the next usage 5 Store the air compressor in its normal operating position in a dry and protected area WARNING Water will condense in the air compressor tank when the compressor is in operation Water left in the tank can cause the tank...

Страница 11: ... Air obtained directly from the air compressor should never be used to supply air for human consumption Risk of bursting Do not adjust regulator to result in output pressure greater than marked maximum pressure of attachment Do not use at pressure greater than 8 bar 116 psi Hot surface To reduce the risk of injury or damage avoid contact with any surface This compressor may start without warning R...

Страница 12: ...d switch Turn off the onboard switch which releases line pressure and turn on from the onboard switch Current limiting protector open Unplug compressor and let thermal fuse cool for 5 min Current limiting protector cuts out repeatedly Low voltage Check with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension...

Страница 13: ...ormal Broken inlet valves Take compressor to service centre Connections leaking Tighten connections Hose or tool leaking Check replace leaking hose tool Current limiting protector open on one of the motors Unplug unit from the wall and allow to cool for 5 minutes ...

Страница 14: ...14 14 PARTS LIST ...

Страница 15: ...lid 1 10 Air filter 1 33 Protection ring 11 1 Pressure switch 26 Bolt 1 11 Obturating ring 1 34 Bolt 11 2 Safety valve 27 Tank 1 12 Cylinder head 1 35 Bolt 11 3 Regulator 28 Nut 1 13 Bolt 1 36 Right crankcase 11 4 Quick valve 29 Spring washer 1 14 Obturating ring 1 37 Bolt 11 5 Connect 30 Washer 1 15 Connecting pipe 1 38 Spring 11 6 Pressure gauge 31 Washer 1 16 Elbow 1 39 Stator 11 7 Connector 32...

Страница 16: ...htronic Industries N Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand www aegpowertools com au www aegpowertools co nz AEG is a registered trade mark used under license from AB Electrolux publ NITTO is a registered trade mark owned by Nitto Kohki Co Ltd 20220304v1 ...

Отзывы: