 WARNING

Always wear eye protection with side shields. Failure to do so could 
result in objects being thrown into your eyes resulting in possible 
serious injury.

 

 WARNING

Always release all pressure, disconnect from power supply, and 
allow unit to cool before cleaning or making repairs on the air 
compressor.

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most plastics are 

susceptible to damage from various types of commercial solvents and 

may be damaged by their use. Use clean cloths to remove dirt, dust, 

oil, grease, etc.
Do not modify this product in any way or use accessories not 

approved by the manufacturer. Your safety and that of others may 

be compromised.
Disconnect the power supply before making adjustments or when 

doing any maintenance on the machine.

 

 WARNING

Do not at any time let brake fluids, gasoline, petroleum-based 
products, penetrating oils, etc., come in contact with plastic parts. 
Chemicals can damage, weaken or destroy plastic which may result 
in serious personal injury.

REPLACING AIR FILTERS

See figure 12.

Follow the instructions below to replace the air filters:

Normal environment

Check and clean the filters once a month. Replace damaged or heavily 

clogged filters.

Heavy-dust environment

Check and clean the filters once a week. Replace damaged or heavily 

clogged filters.

To replace an air filter:

1.  Remove the air filter by turning counterclockwise.
2.  Attach a new air filter and rotate clockwise to secure.

 

 WARNING

For greater safety and reliability, all repairs should be performed by 

an authorised AEG service centre.

Use only AEG accessories and spare parts. Should components need 

to be replaced which have not been described, please contact one of 

our AEG service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the product can be ordered. Please 

state the Article No. as well as the machine type printed on the label 

and order the drawing at your local service agents or directly at: 

Techtronic Industries Australia Pty Ltd

PO Box 1065 

Mount Waverley VIC 3149 

Tel. no. 1300 234 797 

Australia

Techtronic Industries N.Z. Limited

PO Box 12-806 

Penrose AUCKLAND 1642 

Tel. no. 0800 234 797 (0800 AEGPWR) 

New Zealand

SYMBOLS

Safety alert

Please read the instructions carefully before starting 

the machine.

Always wear goggles when using the machine.

Wear ear protectors.

Regulatory Compliance Mark (RCM). Product meets 

applicable regulatory requirements.

Indoor use

Wet condition alert. Do not expose to rain. Store 

indoors.

Risk of breathing. Air obtained directly from the air 

compressor should never be used to supply air for 

human consumption.

Risk of bursting. Do not adjust regulator to result 

in output pressure greater than marked maximum 

pressure of attachment. Do not use at pressure 

greater than 10 bar (145 psi).

Hot surface: To reduce the risk of injury or damage, 

avoid contact with any surface.

This compressor may start without warning.

Risk of fire or explosion.

 Spray area must be well 

ventilated. Do not smoke while spraying or spray 

where spark or flame is present. Keep compressors 

as far from the spraying area as possible. Keep 

compressor, at least 10 m from the spraying area 

and all explosive vapours.

Caution, risk of electric shock

Do not dispose of electric tools together with 

household waste material. Electric tools and 

electronic equipment that have reached the end of 

their life must be collected separately and returned 

to an environmentally compatible recycling facility.

Содержание AC1030S

Страница 1: ...AC1030S Original instructions ...

Страница 2: ...2 2 Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modifications ...

Страница 3: ...3 5 1 2 6 1 Air filter assembly 1 Front handle 2 Handle slot 3 Bolt 1 Rubber foot 2 M8 flat washer 3 M8 bolt 4 M8 hex nut 1 Air filter assembly x2 2 Pressure relief valve 3 Power cord 4 Front handle 5 AUTO OFF switch 6 Pressure regulator knob 7 Regulator pressure gauge 8 Tank pressure gauge 9 Quick connect coupler 10 Tank 11 Rubber foot x2 12 Wheel x2 13 Rear handle 14 Drain valve ...

Страница 4: ...oupler 2 Quick connect air fitting 3 To close counterclockwise 4 Pressure relief valve 5 Regulator locking ring 1 Quick connect air fitting 2 Quick coupler 1 AUTO position 2 OFF position 3 Tank pressuse gauge 4 Regulated pressure gauge 5 To open clockwise 6 Regulator locking ring 2 ...

Страница 5: ... 3 2 1 2 3 Fig 12 Fig 10 Fig 11 1 1 Pressure relief valve 2 To close 3 To release air 1 Air filter housing 2 Air filter 3 Air filter cover 4 Air hose 1 Drain valve 2 Open position 3 Closed position 2 3 4 1 ...

Страница 6: ... it is in operation Do not use in dangerous environments Do not use power tools in damp or wet locations or expose to rain Keep the work area well lit Keep children and visitors away All visitors should wear safety glasses and be kept a safe distance from work area Do not let visitors contact tool or extension cord while operating Never use in an explosive atmosphere Normal sparking of the motor c...

Страница 7: ...l unattended with the air hose attached Never point any air tool toward yourself or others Do not operate this air compressor if it does not contain a legible warning label Do not continue to use a tool or hose that leaks air or does not function properly Always disconnect the air supply and power supply before making adjustments servicing a product or when a product is not in use Do not attempt t...

Страница 8: ... on this list are not assembled to the product by the manufacturer and require customer installation Use of a product that may have been improperly assembled could result in serious personal injury Inspect the product carefully to make sure no breakage or damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operated the product W...

Страница 9: ...CTING AIR HOSE See figure 7 NOTE For operation using pressures above 7 bar 102 psi delivery hoses should be fitted with a safety cord e g wire rope 1 Make sure the air compressor is off and unplugged 2 Rotate pressure regulator knob fully counterclockwise 3 Rotate regulator locking ring fully counterclockwise 4 Confirm that the outlet pressure is at zero 0 bar 5 Attach hose with quick connect air ...

Страница 10: ...lockwise and the air should stop escaping Keep the pressure relief valve clean and do not cover it with any object WARNING If air leaks after the pressure relief valve has been closed or if the valve is stuck and cannot be actuated do not use the air compressor until the pressure relief valve has been replaced Use of the air compressor in this condition could result in serious personal injury DRAI...

Страница 11: ...eed to be replaced which have not been described please contact one of our AEG service agents see our list of guarantee service addresses If needed an exploded view of the product can be ordered Please state the Article No as well as the machine type printed on the label and order the drawing at your local service agents or directly at Techtronic Industries Australia Pty Ltd PO Box 1065 Mount Wave...

Страница 12: ...ned off at the mains before the onboard switch Turn off the onboard switch which releases line pressure and turn on from the onboard switch Current limiting protector cuts out repeatedly Low voltage Check with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge wire and cord lengt...

Страница 13: ...PROBLEM POSSIBLE CAUSE SOLUTION Air output lower than normal Broken inlet valves Take compressor to service centre Connections leaking Tighten connections Hose or tool leaking Check replace leaking hose tool ...

Страница 14: ...13 14 15 19 20 23 24 25 26 27 28 31 32 33 34 5 2 36 37 38 39 40 42 41 22 29 17 18 16 56 57 58 59 53 63 62 64 65 66 52 50 49 47 77 76 75 78 51 79 60 61 68 71 69 72 73 74 45 46 48 55 43 44 67 70 30 35 54 82 83 86 85 84 81 80 PARTS LIST ...

Страница 15: ...er 32 Bearing 6908 54 Connector 76 Nut 11 Cylinder obturating ring 33 Bolt M8 10 55 Pressure gauge 77 Bolt M8 12 Cylinder cover obturating ring 34 Snap ring 56 High pressure pipe 78 Handle 13 Cylinder head 35 Right crankcase 57 Check valve 79 Handle cover 14 Hexagon socket head screw M6 70 36 Bolt M5 192 58 Unloading pipe 80 Spring washer 15 Spring washer 37 Spring washer 59 Protection ring 81 Was...

Страница 16: ...htronic Industries N Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand www aegpowertools com au www aegpowertools co nz AEG is a registered trade mark used under license from AB Electrolux publ NITTO is a registered trade mark owned by Nitto Kohki Co Ltd 20210802v1 ...