Problem
Possible cause
Solution
There is no voltage in the mains
socket (try to connect another
appliance into it)
Call an electrician
The appliance is not switched on Switch on the appliance
Temperature Regulator is not on Check the Temperature Regulator
Green indicator flashing
Temperature sensor problem
Call the service personnel
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets. Contact the Service Center.
TECHNICAL DATA
Dimension
Height
850 mm
Width
595 mm
Depth
635 mm
Rising Time
24 h
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.
INSTALLATION
WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the appli
-
ance before installing the appliance.
Positioning
This appliance can be installed in a dry, well ventilated indoor (garage or cellar) also, but for
optimum performance install this appliance at a location where the ambient temperature
corresponds to the climate class indicated on the rating plate of the appliance:
Climate class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C