background image

13

Mounting the cooker hood - Fig. 7

Position the template on the wall and mark the position, and drill the holes (2
x Ø 8 mm).Mount the two rawl plugs with the hooks (3)
Hang the hood on the hooks and level it with the adjustment screws (4)
Remove the grease filters (5) and mark for the two screws (6). Remove the hood
and drill the holes (2 x Ø 8 mm).
Insert the rawl plugs (7) and hang the hood on the wall again. Adjust it
horizontally with the screws (8) and secure it with the screws (9)
Mount the chimney holder (10) with the rawl plugs (12) and the screws (11).
Be careful that it is centered over the hood and horizontally aligned.

Fitting for ducting (S)

Connect a tube between the hood air outlet and the wall or roof exhaust
channel. Fix it with the tube clamps supplied.

Fitting for recirculation (K)

Mount the recirculation spigot with the two screws supplied.

Mounting the chimney

Place the chimney (15) and fix it to the top chimney holder with the two
screws (16) supplied. Lower the bottom part of the chimney (17) and fasten
it to the top of the hood with two screws, supplied. 
Note that the top part of the chimney can be mounted with the side grids up
or down. For use as a recirculation hood it must be mounted with the grids
upwards. (Fig. 6).

Fig. 6

Содержание 8490 D

Страница 1: ...8490 D Cooker hood Operating and Installation Instructions ...

Страница 2: ...or left to another person Installation and service Any electrical installation of the cooker hood must be carried out by a qualified electrician and the hood itself must be installed by someone with experience Installation made by an unqualified person can lead to loss of function of the cooker hood and possible damage to person and and or property The cooker hood must be at least 50 cm above elec...

Страница 3: ...evacuation duct Recirculation using an optional carbon filter Disposal Prevent accidents when disposing of your cooker hood Disconnect the power plug from the wall socket and cut the power cord at the hood inlet Contact your local authority for information on where to dispose of the cooker hood Use of cooker hood This appliance is for domestic use only in a normal household Never leave any deep fr...

Страница 4: ...ch Function at displayed SENSOR If the hand is moved over the sensor or the knob T4 is pressed the light is switched on and the motor starts to run on second speed Speed changes can be made with the knobs T4 T5 If the hand is again mowed over the sensor the light and motor is switched off If when stand by mode is activated the knob T5 is pressed the intensive speed is started and the light is swit...

Страница 5: ...nds The saturation indicator is reset when F or C turn off on the display Caution the appliance is not set to indicate saturation of the charcoal filter If you decide to use it in recirculation mode with charcoal filter signalling of filter saturation must be set as follows turn the hood OFF then press T5 and T6 simultaneously for 3 seconds Correct ventilation If the cooker hood is to work correct...

Страница 6: ... on which the grease collects Clean thefilterinhotwaterusingadetergent or in a dishwasher Let the filter dry before putting it back Note that a dishwasher may discolour the filter Changing and cleaning the carbon filter Only applicable for recirculation The carbon filters absorb smells and odours Unlike other carbon filters the LONGLIFE carbon filter can be cleaned and reactivated At normal use th...

Страница 7: ...pproximately three years of use the KF8 filter should be replaced with a new as the odour reduction capacity will be reduced To remove the filter Fig 4 Remove the grease filters Press the red buttons A lower the front of the carbon filter Remove the carbon filter Replace in reverse order Fig 5 Fig 4 Clean the filters regularly The grease that collects in the filters and the duct could ignite if a ...

Страница 8: ...ck that the ducting and outlets are not blocked The cooker hood has switched off The safety cut out service has been duringoperation tripped Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damagethehood If after all these checks the problem persists contac...

Страница 9: ...roof of purchase is required for in guarantee service calls Help us to help you Please determine your type of enquiry before writing or telephoning When you contact us we need to know Your name Address and post code Telephone number Clear and concise details of the fault Name and model of the appliance E number This information can be found on the rating plate which can be seen when the grease fil...

Страница 10: ...sed agent AEG reserves the right to stipulate the place of the repair i e the customer s home place of installation or AEG workshop 4 The guarantee or free replacement includes both labour and materials 5 Repairs carried out under guarantee do not extend the guarantee period for the appliance Parts removed during guarantee repairs become the property of AEG 6 The purchaser s statutory rights are n...

Страница 11: ...609 Carbon filter KFL 60 80 610 899 421 Before you move please contact your nearest Customer Care Centre listed below to give them details of your new home They will then ensure that the localServiceOrganisationisawareofyourmoveandabletolookafteryouand yourappliances France Senlis 33 0 44 62 29 29 Germany Nürnberg 49 0 911 323 2600 Italy Pordenone 39 0 1678 47053 Sweden Stockholm 46 0 8 738 7910 U...

Страница 12: ...onnection The electric outlet should be placed inside the chimney The hood has a power cable 100 cm with an earth connection and the rated voltage is 220 240 V Connect the hood to the mains supply via a double pole switch which has 3 mm minimum clearance between the contacts 220 240 V The following is valid in the United Kingdom only As the colours of the wires in the mains lead of this appliance ...

Страница 13: ...lugs 12 and the screws 11 Be careful that it is centered over the hood and horizontally aligned Fitting for ducting S Connect a tube between the hood air outlet and the wall or roof exhaust channel Fix it with the tube clamps supplied Fitting for recirculation K Mount the recirculation spigot with the two screws supplied Mounting the chimney Place the chimney 15 and fix it to the top chimney holde...

Страница 14: ...14 Fig 7 12 12 ...

Страница 15: ...15 Fig 8 Power outlet Exhaust tube Electrichob 500mm Gashob 650mm Charcoalandoil 700mm Wall bracket Electrichob 500mm Gashob 650mm Charcoalandoil 700mm ...

Страница 16: ...AEG Hausgeräte GmbH Postfach 1036 D 90327 Nürnberg http www aeg hausgeraete de Copyright by AEG LI1IAE ...

Отзывы: