background image

16

A)

End of shaft with nut

B)

Washer

C)

Elbow

FO 0814

FO 0264

On the end of the shaft, which includes the G 1/2" threaded elbow,

adjustment is fixed so that the washer is fitted between the components

as shown in the diagram. Screw the parts together without using

excessive force.

It is important to install the elbow correctly, with the shoulder on

the end of the thread, fitted to the hob connecting pipe.
Failure to ensure the correct assembly will cause leakage of gas.

Gas Connection

Connection to the gas supply should be with either rigid or semi-rigid

pipe, i.e. steel or copper.
The connection should be suitable for connecting to RC 1/2 (1/2 BSP

male thread).
When the final connection has been made, it is essential that a thorough

leak test is carried out on the hob and installation.
Ensure that the main connection pipe does not exert any strain on the

hob.

Installation

Содержание 34942G

Страница 1: ...s de cuisson Gaskookplaten Piani di cottura PERFEKT IN FORM UND FUNKTION Operating and Installation Instructions Notice d utilisation et d encastrement Gebruiksaanwijzing en Installatievoorschrift Istruzioni per l uso e l installazione GB FR NL IT ...

Страница 2: ...r Removeallpackagingbeforeusingthehob Ensurethatthegasandelectricalsupplycomplieswiththetypestatedon theratingplate locatednearthegassupplypipe Donotattempttomodifythehobinanyway ChildSafety Thishobisdesignedtobeoperatedbyadults Donotallowchildrento playnearorwiththehob Thehobgetshotwhenitisinuse Childrenshouldbekeptawayuntilithas cooled Childrencanalsoinjurethemselvesbypullingpansorpotsoffthehob ...

Страница 3: ...useanaccidentbytippingorspillage Neverleavethehobunattendedwhencookingwithoilandfats Neveruseplasticoraluminiumfoildishesonthehob Perishablefood plasticitemsandareosolsmaybeaffectedbyheatand shouldnotbestoredaboveorbelowthehobunit Service ThishobshouldonlyberepairedorservicedbyanauthorisedService Engineerandonlygenuineapprovedsparepartsshouldbeused EnvironmentalInformation Afterinstallation please...

Страница 4: ...gineerstechnicaldata 12 Importantsafetyrequirements 14 Location 14 Installation 15 GasConnection 16 CutOutSize 17 Building In 17 Buildingoveracupboardordrawer 17 Building over a kitchen unit with door 18 Fitting the hob to the worktop 19 Electricalconnections 20 PermanentConnection 21 Wiringdiagram 21 FaultFinding 22 PreliminaryElectricalSystemsCheck 22 IgnitionSystem GasIgnition 24 Commissioning ...

Страница 5: ...ectives 73 23EEC 90 683EEC 93 68EEC 89 336EEC 90 396EEC current edition GuidetoUsetheinstructions The following symbols will be found in the text to guide you throughout the Instructions SafetyInstructions Step by step instructions for an operation HintsandTips ...

Страница 6: ...er rapid Description of the Hob Mod 34942 G INSTALLATION AnygasinstallationmustbecarriedoutbyaregisteredCORGI installer and in accordance with existing rules and regulations The relevant instructions are to be found in the second section of this manual Please ensurethat oncethehobisinstalled itiseasilyaccessiblefor the engineer in the event of a breakdown WHENTHEHOBISFIRSTINSTALLED Oncethehobhasbe...

Страница 7: ...eed before putting a pan on the pan support Tolightaburner turntherelevantknobanticlockwisetomaximumposition thenpushitdowntoignitetheburner Uponignition adjusttheflame asrequired If the burner does not ignite turn the control knob to zero and try again When switching on the mains after installation or a power cut it is quite normal for the spark generator to be activated automatically In the even...

Страница 8: ...steelwoolpads bath sinkstainremovers Shouldthehobtopbecomeheavilysoiled itisrecommendedthata cleaningproductsuchasHobBriteorBarKeepersFriendisused PanSupports Whenwashingthepansupportsbyhand takecarewhendryingthem astheenamellingprocessoccasionallyleavesroughedges Ifnecessary removestubbornstainsusingapastecleaner TheBurners Theburnercapsandcrownscanberemovedforcleaning Washtheburnercapsandcrownsu...

Страница 9: ...burnercapandcrown havebeenreplacedcorrectly e g aftercleaning Checkthemainjetisnotblocked and the burner crown is clear of foodparticles Checktheburnercapandcrown havebeenreplacedcorrectly e g aftercleaning If after all these checks your hob still does not operate correctly contact yourlocalAEGServiceForceCentre Please note that it will be necessary to provide proof of purchase for any in guarante...

Страница 10: ...0 5 929 929 Your call will be routed to your local Service Force Centre For the address of your local Service Force Centre and further information about Service Force please visit the website at www serviceforce co uk CUSTOMER CARE For general enquiries concerning your AEG appliance and for further information on AEG products contact our Customer Care Department by letter or telephone at the addre...

Страница 11: ...ovable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of AEG manufacture which are not marketed by AEG European Guarantee If you should move to another country within Eu...

Страница 12: ... IGNITIONHTSPARK SparkGenerator IspraControl sBF50066 230 240V 0 6YA T120 SparkGap Fixed HEATINPUT Rear Left Burner semi rapid 2 0 kW 6824 BTU HR Front Left Burner rapid 3 0 kW Natural Gas 10236 BTU HR 2 8 kW L P G 9554 BTU HR Central Burner triple crown 4 0 kW 13652 BTU HR Rear Right Burner semi rapid 2 0 kW 6824 BTU HR Front Right Burner auxiliary 1 0 kW 3412 BTU HR APPLIANCECLASS 3 APPLIANCECA ...

Страница 13: ... 0 0 45 1 0 0 33 4 0 1 2 NOMINAL FLOW RATE m3 h 0 286 0 057 0 190 0 038 0 095 0 028 0 381 0 114 NOZZLE REFERENCE 119 Adjust 96 Adjust 70 Adjust 146 Adjust 1 100 mm NOMINALTHERMAL POWER kW 2 8 0 65 2 0 0 45 1 0 0 33 4 0 1 2 NOMINAL FLOW RATE g h 202 43 5 144 29 72 21 5 252 86 NOZZLEREFERENCE 86 40 71 32 50 28 98 56 1 100 mm NATURALGAS 20mbar VALUE 37 78MJ m3 Ws 50 7MJ m3 TYPEOFGAS LPGGAS 28 30 37mb...

Страница 14: ... door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before mak...

Страница 15: ...lified personnel to the relevant British Standards Any gas installation must be carried out by a CORGI registered installer The manufacturer will not accept liability should the above instructions or any of the other safety instructions incorporated in this book be ignored 700 mm 420 mm 100 mm 420 mm 50 mm 50 mm 55 mm 650 mm 420 mm 420 mm 100 mm 50 mm 50 mm 55 mm FO 2027 FO 2028 700 mm Installatio...

Страница 16: ...oulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to RC 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak te...

Страница 17: ...f the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on theundersideoftheworksurface It is also recommended to carry out the electrical connection to the hobasshownindiagrams1and2 seenextpage Building in 830 470 55 min 860 500 FO2407 ...

Страница 18: ...e unit in order to avoid any contact with the bottom of the hob which canbeheatedwhenitisoperated Therecommendedsolutionis shownindiagram3 The panel fitted under the hob a shouldbeeasilyremovable toalloweasyaccessiftechnical assistanceisneeded Thespace behind the kitchen unit b can beusedforconnections 30 20 min 60 a b FO1013 3 Dimensionsaregiveninmm Building in ...

Страница 19: ...tial that no gaps are left in this seal in order to preventspillagenearthehob seepingintothecabinetbelow 1 Placethesealing gasketallaroundthe edge of the cut out 2 Placethehobinto the cut out and secureitbymeansof the relevant fixing clampsandscrews as showninthediagram 3 Removetheexcessseal Theedgeofthehobformsadoublesealwhichpreventstheingressof liquids FO0199 a Seal ...

Страница 20: ... 3ampASTA approved BS1362 fusemustbeused Shouldtheplugneedtobereplacedfor anyreason thewiresinthemainslead arecolouredinaccordancewiththe following code GreenandYellow Earth Blue Neutral Brown Live 1 Connectthegreenandyellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow 2 Connect the blue neutral wire to the terminal in th...

Страница 21: ...nsure that the hob supply cord does not come into contact with surfaceswithtemperatureshigherthan50deg C Wiringdiagram 1 TAPSIGNITORSWITCHES 2 IGNITORUNIT 2 1 L N 0 220 240 1 2 3 4 5 N Replacementofthecable The connection of the voltage cable to the appliance s terminal block isoftype Y Thismeansthatitsreplacementrequiresthespecific equipmentofatechnician Inthiscase onlycabletypeH05RR Fmustbeused ...

Страница 22: ... Electricity supply shouldnowbe satisfactory Carry out D Resistanceto Earthcheck Inlet wiring faulty Rectifyany fault Isolateapplianceand carry out B Insulationcheck Rectify any fault including replacing fusesasnecessary NO Y E S SOCKET faceview PLUG withcoverremoved EarthWire Green Yellow NeutralWire Blue FUSE E N L Brown Blue Green Yellow Green Yellow Brown Blue NO Y E S ...

Страница 23: ...adsfromLtoNinapplianceterminalblock Ifmeterreads 0 thenthereisashortcircuit b metersetoný Ohm x100scale Repeat test with leads from Lto E If meter reads less than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated adetailedcontinuitycheck i e bydisconnectingandcheckingeach component is required to trace the faulty component It is possible that a fa...

Страница 24: ...simmer adjusted Light burner manually Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 5 on the ignitor unit Check for breaks in the insulation oftheH...

Страница 25: ...2 Removethecontrolknob 3 Theadjustmentscrewislocated down the centre of the gas tap control shaft Toadjust useathinbladed screwdriverandturnthe adjustment screw until the flame issteadyanddoesnotextinguish when the knob is turned from MINtoMAX Repeatthis procedureforallburners PressureTesting 1 Remove left hand pan support and front left burner cap and crown 2 Fit manometer tube over the injector ...

Страница 26: ...ctricity supply 3 Removeallpansupports burnercaps rings crownsandcontrolknobs 4 With the aid of a 7mm box spanner the burner injectors can then be unscrewedandreplacedbytheappropriateLPGinjectors TOADJUSTTHEGASRATE With the aid of a thin bladed screwdriver completely tighten down the bypassadjustmentscrew whichislocateddownthecentreofthegas tap control shaft Upon completion stick the replacement r...