A
E
C
B
D
F
Minimum distances
Dimension
mm
A
650
B
150
C
2
D
400
E
450
F
less than 400
13.3
Levelling of the appliance
Use small feet on the bottom of
appliance to set the appliance top
surface level with other surfaces.
13.4
The stability chain
CAUTION!
Install the stability chain to
prevent the appliance from
tilting. The stability chain
only works when the
appliance is put in a correct
area.
1.
Measure down 180 mm from the
appliance top surface, then measure
right 30 mm.
2.
Mark the position of the wall and this
gives anchor point for the stability
chain.
30 mm
180 mm
13.5
Other technical data
WARNING!
These instructions are only
valid in the countries whose
symbols appear on this
booklet's cover.
Gas cate-
gory:
I2H
Gas sup-
ply
G20 (2H) 20 mbar
13.6
Gas burners
BURNER
NORMAL POWER
kW
Natural Gas
INJECTOR MARK 1/100
mm
Btu/h
Auxiliary
1
70
3412
Semi-rapid
1.9
96
6483
www.aeg.com
26
Содержание 17166GT-MN
Страница 1: ...EN User Manual Cooker 17166GT MN ...
Страница 31: ...ENGLISH 31 ...
Страница 32: ...www aeg com shop 867319442 C 322015 ...