User Manual 1-3kVA Rev. 9 

 

                                - Page 28 of Total 30 -                                 

 

 

6. Appendix 

6.1 Specifications 

`

 

General Specification 

 

Specifications

 

Model No. 

ST3

200

 (tower) 

ST

3200R

 (rack-mount) 

ST3

200

 (tower) 

ST3

200R

 (rack-mount) 

ST3

200

 (tower) 

ST3

200R

 (rack-mount) 

Topology 

True On - Line , Double Conversion 

On- battery Output Waveform   

Pure Sine Wave 

Number of Phase 

Single ( 1 

Φ

 2W + G ) 

Input

 

 

Maximum Capacity ( VA / W ) 

1000 VA / 700 W 

2000 VA / 1400 W 

3000 VA / 2100 W 

Nominal Input Voltage 

230 VAC 

Input Voltage Regulation 

160~300 VAC Single Phase w/ Ground 

Nominal Input Frequency 

50/60 ± 4 Hz 

Input PFC 

 0.95 

Input Short Protection 

Circuit Breaker 

Output

 

Nominal Output Voltage 

220 / 230 / 240 VAC nominal     

Output Voltage Regulation 

  + / - 2 % 

Output T.H.D 

3% ( Linear Load) 

4% THD ( Linear Load) 

 

 

6% ( Non-Linear Load) 

7% THD ( Non-Linear Load) 

High Efficiency Mode ( AC to AC ) 

85% 85% 88% 

High Efficiency Mode ( DC to AC ) 

83% 83% 83% 

Crest Factor 

3 : 1 

Start on Battery 

Yes 

Output Frequency 

50 Hz + / - 0.2 Hz 

Overload 

Sustaining 30 sec @ 125%~150% load; 200ms @ >150% load 

Battery   

Typical Backup Time ( Full load ) 

5 minutes 

9 minutes 

5 minutes 

Battery Type 

Sealed Lead-Acid maintenance-free 12VDC/7AH per cell 

Numbers of Batteries 

3 cells 

8 cells 

Recharge Time to 90% 

5 hours 

Advance Warning Diagnostics

 

 

Front Panel Indication - LCD 

UPS Status, I/P Voltage & Frequency, O/P Voltage & Frequency, Battery Voltage, 

Battery Capacity, Loading %, Temperature, History Alarm. 

Front Panel Indication - LED 

Normal ( Green ), Warning ( Yellow ), Fault ( Red ) 

Audible Alarms 

Battery Mode,    Low Battery, Overload, Fault 

Communication Interface

 

 

Communication port 

RS232 (Standard); DB9 or USB or AS400 or SNMP / HTTP(Optional) 

SNMP Manageable 

Yes 

Environmental

 

 

Operation Temperature 

0-40

 

Storage Temperature 

  - 15 to 50 

 

Relative Humidity 

20% to 90 % Non-Condensing 

Audible Noise   
( at 1 meter from surface of unit ) 

< 45 dBA @ 1 meter 

< 50 dBA @ 1 meter 

Mechanical

 

 

Tower Dimensions ( W x H x D 
mm )   

160 x 220 x 400 

200 x 352 x 450 

200 x 352 x 450 

440 x 88 x 465 ( UPS only ) 

Rack-mount Dimensions 
( W x H x D mm ) 

440 x 88 x 465 

( w/ internal battery ) 

440 x 88 x 465 ( External Battery Module ) 

Tower Weight ( Net weight with 
Battery ) ( kgs ) 
 

15 34 35 

Rack Mount  Weight ( Net weight 
with Battery ) ( kgs ) 

15.5 

35 

36 

Содержание ST3010

Страница 1: ...User Manual 1kVA 3kVA 220VAC...

Страница 2: ...USB Card 13 DB9 Dry Contact Card 13 AS400 Card 14 SNMP HTTP Agent 14 3 Operation 15 3 1 LCD and LED Display 15 LCD 15 LED 17 3 2 Starting up Shutting down the UPS 18 3 3 Operating Modes 19 3 4 Configu...

Страница 3: ...F 0o C to 40o C The UPS is designed for data processing equipment It is not intended for use with life support and other designated critical devices The maximum load must not exceed that shown on the...

Страница 4: ...as it supplies reliable pure and stable power at an affordable price Feature Benefits 9 True on line double conversion 9 PWM technologies w IGBTs 9 Wide input voltage range 9 DC Start 9 Battery self...

Страница 5: ...User Manual 1 3kVA Rev 9 Page 2 of Total 30 1 Presentation 1 2 System Configuration Tower 1kVA 160W x 220H x 400D mm 15 kgs 2kVA 200W x 352H x 450D mm 34 kgs 3kVA 200W x 352H x 450D mm 35 kgs...

Страница 6: ...User Manual 1 3kVA Rev 9 Page 3 of Total 30 1 Presentation Rack Mount 1kVA 440W x 88H x 465D mm 15 5 kgs 2kVA 440W x 88H x 465D mm 35 kgs 3kVA 440W x 88H x 465D mm 36 kgs...

Страница 7: ...ult LED red 5 Select up button 6 Select down button 7 Enter button 5 6 Off button 6 7 On button 5 7 Test Silence button LED 1 2 3 4 5 6 7 8 9 1 Line LED green 2 Load Battery Capacity LEDs 3 Battery LE...

Страница 8: ...tal 30 1 Presentation 1 3 2 Rack Mount 1 2 3 4 5 6 7 1 2 line LCD Display 2 Normal LED green 3 Warning LED yellow 4 Fault LED red 5 Select up button 6 Select down button 7 Enter button 5 6 Off button...

Страница 9: ...2 8 7 9 9 2 8 9 10 3 4 4 4 5 5 5 3 3 1kVA 2kVA 3kVA 1 Standard RS232 Port 2 Fan 3 External Battery Slot Option 4 Input Breaker 5 Inlet 6 Communication ports DB9 USB AS400 SNMP HTTP Option 7 Surge Prot...

Страница 10: ...2 5 9 7 1 8 3 2 long run time kVA 4 3 6 2 5 9 7 1 8 11 10 1 External Battery Slot Option 2 Outlets IEC 10A Germen 3 Inlet 4 Input fuse 5 Fan 6 Communication Ports DB9 USB AS400 SNMP HTTP Option 7 LCD...

Страница 11: ...User Manual 1 3kVA Rev 9 Page 8 of Total 30 1 Presentation External Battery Bank or Module For Tower Product ranges For Rack Mount product ranges...

Страница 12: ...l batter 1 Box ST 3200R Rack Mount N A internal battery 1 Box ST 3200R Rack Mount 1 Battery Module 2 Boxes ST Series 1kVA 3kVA Tower Box 1 c d e f Shipping Box Includes 1 UPS 2 User Manual 3 Input Pow...

Страница 13: ...ng Box Includes 1 UPS 2 User Manual 3 Input Power Cord German British Australian 4 Extension Power Cord IEC to PC for output receptacles IEC only 5 2pcs 19 rack ears screws Box 2 for 2 3kVA Rack Mount...

Страница 14: ...DSL Remote control USB To external battery cabinet DB9 Output to the loads To the wall socket SNMP HTTP Rack Mount To the wall socket Optional Communication Slot Output to the load To external battery...

Страница 15: ...h specific monitoring software installed Please contact a sales representative for further information of monitor software The pins of the connector are as following The RS 232 interface settings are...

Страница 16: ...B9 Dry Contact Card USB Card AS400 Card and SNMP HTTP Card USB Card DB9 Dry Contact Card Pin Definition of DB9 for NOVELL Interface PIN of DB9 Function explanation I O 1 UPS Fault Output 3 GND Input 4...

Страница 17: ...rom the NetAgent Mini CD on a Windows environment and configure the IP address All the other configurations could be accomplished in a Web browser NetAgent Mini also provides shutdown programs for dif...

Страница 18: ...0V 50Hz Display 3 UPS Status AC FAIL BATT LOW NO Output Display 4 Real Input Output Voltage and Frequency Input Voltage 220 VAC Output Voltage 220VAC Input Frequency 50 Hz Output Frequency 50 Hz Selec...

Страница 19: ...ty 100 Display 6 Output Power Output Power 100 Display 7 Inside Temperature Inside TEMP 33 91 Display 8 New Alarm NEW AC Fail 1 ALM Overload 3 Display 9 Old Alarm OLD AC Fail 5 ALM Overload 9 Display...

Страница 20: ...LED green This indicates the inverter is working normally 6 10 Load Battery Capacity LEDs a No 6 to 7 LED is green color No 8 to 9 is yellow and No 10 used as warning LED for overload or battery low i...

Страница 21: ...rmal Mode the UPS is ready for operation Shutting down the UPS Press the Select up Select down button simultaneously for one second The UPS will turn off DC Start up of the UPS Step 1 Without connecti...

Страница 22: ...The AC output power comes from AC utility input and passes through AC DC rectifier DC AC inverter and static switch to support power to load The battery charging voltage comes from AC utility input an...

Страница 23: ...User Manual 1 3kVA Rev 9 Page 20 of Total 30 3 Operation Bypass Mode Under the following conditions the bypass will be enabled 1 Overload 2 Inverter failure 3 Over temperature...

Страница 24: ...d Display 11 Output Voltage Frequency Setting Volt Freq Set 220 VAC 50 Hz Display 11 Output Voltage Frequency Setting Volt Freq Set 220 VAC 50 Hz Step 3 Use Select Up or Select Down keys to adjust the...

Страница 25: ...I voltage settings Display 10 Bypass Voltage Setting Bypass Volt Set LO 176V HI 253V Step 2 The cursor will pop up to indicate the item newly selected Press the Enter key to select the item either HI...

Страница 26: ...an ambient temperature range of 32 F to 104 F 0 C to 40 C Keep the UPS on a flat stable surface with a 10cm space around it for proper ventilation Do not place the unit near a heat source also avoid p...

Страница 27: ...Use tools with insulated handles Do not lay tools or metal parts on top of batteries Do not attempt to alter any battery wiring or connectors Attempting to alter wiring can cause injury Do not dispose...

Страница 28: ...t 1 Please contact with sale representative 2 Remove short circuit condition restart the UPS Fault Warning Normal y UPS stop working y The alarm beeps continuously AC OK BATT OK DC_BUS Fail 1 Power Bo...

Страница 29: ...every 4 seconds AC Fail BATT OK Battery Mode 1 AC utility power fail 2 Input cable broken or disconnect with UPS 1 If AC utility power fails reduce the load in order to extend backup time 2 If it is...

Страница 30: ...e UPS y Inverter LED illuminated y Alarm sounds every 4 second 1 AC utility power fail 1 UPS go to battery mode automatically 2 As the audible alarms per every 1 second battery is almost empty y Fault...

Страница 31: ...50 load Battery Typical Backup Time Full load 5 minutes 9 minutes 5 minutes Battery Type Sealed Lead Acid maintenance free 12VDC 7AH per cell Numbers of Batteries 3 cells 8 cells Recharge Time to 90 5...

Страница 32: ...45 34 26 3 EB 24pcs 1110 488 299 210 159 96 66 49 39 Rack Mount RUN TIME CHART in Minutes Output load UPS Model 200 VA 140 W 400 VA 280 W 600 VA 420W 800 VA 560W 1000 VA 700 W 1500 VA 1050 W 2000 VA...

Отзывы: