User Manual 1-3kVA Rev. 9
ii
Important Safety Instructions
SAVE THESE INSTRUCTIONS.
This UPS unit operates from utility power and contains a number of high
current back-up batteries, the information is important to all personnel involved.
Please read this manual
before installation and operation of the UPS.
Safety of Persons
Î
Opening or removing the cover of the unit may expose you to lethal voltage within the unit, even if it is
apparently not in operation and the input wiring is disconnected from the electrical source.
Î
Refer all UPS and battery servicing to authorized service personnel from the manufacturer or an agent authorized
by the manufacturer.
Î
Do not dispose of the battery in a fire, as the battery may explode.
Î
Do not open or damage the battery. Battery acid is toxic and harmful to eyes and skin.
Î
The following precautions should be observed when working on batteries:
•
Remove watches, rings, and other metal objects.
•
Use tools with insulated handles.
Product Safety
Î
Install the UPS in a clean environment, free from moisture, flammable gases or fumes and corrective
substances.
Î
Keep the UPS on a flat, stable surface with a
10cm
space around it for proper ventilation.
Î
Operate the UPS in an indoor environment only in an ambient temperature range of
32
o
F to +104
o
F (0
o
C to
+40
o
C)
.
Î
The UPS is designed for data processing equipment. It is not intended for use with life support and other
designated “critical” devices.
Î
The maximum load must not exceed that shown on the UPS rating label.
Î
Storing magnetic media on top of the UPS may result in data loss or corruption.
Î
Once batteries have reached the end of their life, ensure they are disposed of properly.
REFER TO YOUR LOCAL
LAWS AND REGULATIONS FOR BATTERY DISPOSAL REQUIREMENTS.
Î
The UPS must be handled with care and attention since there is high energy stored within the batteries. It must
always be kept in the position marked on the external packaging and must not be dropped.
Î
Please keep the exhaust holes of UPS unobstructed.
Î
The battery should be maintained at regular intervals.
Special Precautions
Î
The UPS should be installed according to the instructions in this manual. Failure to do so could result in safety
issues. It could also invalidate your warranty.
Î
DO NOT CONNECT equipment that could overload the UPS or demand half-wave rectification from the UPS, for
example:
electric drills, vacuum cleaners, printers or hair dryers.
Î
Adjust only those controls that are listed in the Adjustment Section. If the unit does not operate normally by
following the operating instructions, contact the sales representatives.
Icon Usage
These icons may be found in the contents.
WARNING:
Obvious danger to personnel or equipment.
CAUTION:
Possible danger to personnel or equipment
Important information
Содержание ST3010