Non-use Periods:

Object and Liquid Entry

Damage Requiring Service

Servicing:

IMPORTANT NOTES

This manual is to be considered an integral part of the product, and must always accompany the 
speaker when it changes ownership as a reference for correct installation and operation as well as for 
the safety regulations.

dB Technologies will not assume any responsibility for incorrect installation of the speaker.

OPERATING PRECAUTIONS

-

Do not force the amplifier incorporated in the speaker to work in overload for extended periods 

of time.

-

Never force the control elements (switches, controls, etc.).

CAUTION

-

Make sure that the speaker is positioned in a stable and secure way in order to avoid any 

dangerous conditions for persons or objects.

CONNECTION

-

For connecting the speaker, use only qualified and experienced personnel having sufficient 

technical knowledge or specific instructions for making the connections correctly and thus 
preventing electrical dangers.

-

To prevent the risk of electrical shock, the speaker must only be supplied from the mains after all 

connections have been completed.

-

Before powering up the speaker, it is advisable to re-check all the connections, making sure in 

particular that there are no short circuits.

-

The entire sound system must be designed and installed in compliance with the current 

standards and regulations regarding electrical systems.

CAUTION

-

To prevent inductive phenomena from giving rise to hum or disturbance which would jeopardize 

efficient 

seaker operation, the cables that transmit microphone signals or line level signals 

(e.g. 0 dB/V) must be screened and should not be run in the vicinity of:
1)

Equipment that produces strong magnetic fields (e.g. large power supply transformers)

2)

Electrical energy conductors

3)

Lines that supply speakers.

Unplug this apparatus during lightning storms or   when unused for long periods of time.

Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through 
openings.

Refer all servicing to qualified service personnel. Servicing is required when:
-

the apparatus has been damaged in any way;

the power supply cord or the plug has been damaged; 

-

Objects have fallen, or liquid had been spilled into the appliance;

The appliance has been exposed to rain or moisture;

The appliance does not appear to operate normally or exhibits a marked change in 
performance;

The appliance had been dropped.

The user should not attempt to service the appliance beyond that is described in the Operating 
Instructions. All other servicing should be referred to qualified service personnel.

CAUTION

CONTROLS AND FUNCTIONS

1)

POWER  SWITCH

This switch permits turning the speaker on and off.

2)

"MAINS FUSE" FUSE CARRIER

Mains fuse housing.

3)

"MAINS INPUT" POWER SOCKET

For connecting the power cable provided.
The connector used for mains connection is a POWER CON® (blue)

4)

“MAINS OUTPUT LINK” RELAUNCH POWER SOCKET

For relaunching the mains power. The output is connected in parallel with input (3) 
and can be used to power another amplified speaker. 
The connector uses a POWER CON® (grey)

5)

" BALANCED INPUT” INPUT CONNECTOR

Balanced input at line level. It is able to accept “XLR” sockets. 

6)

"BALANCED LINK

/OUT

 ” OUTPUT CONNECTOR

The “XLR” connector connected in parallel with input (5) can be used to send the 
input audio signal to another amplified speaker.

7)

“INPUT SENS” INPUT SENSITIVITY CONTROL

This control regulates the sensitivity of the signal amplifier input. 
This control does not affect the “BALANCED LINK/OUT” output level

8)

“LIMITER” INDICATOR LIGHT

This indicator comes on red to indicate that the internal limiter circuit has tripped. 
This prevents amplifier distortion and protects the speakers against overloads.

9)

“SIGNAL” INDICATOR LIGHT

This indicator comes on green to indicate the presence of the audio signal (at a level 
of -20dB). 

10)

“MUTE

/PROT

” INDICATOR LIGHT

This yellow indicator indicates amplifier status. In normal operating conditions, the 
LED is off; if it flashes or is always on, refer to the diagnostics table to check amplifier 
status.

11)

“READY” INDICATOR LIGHT

This indicator comes on green to indicate that the main power voltage is correct. In 
normal operating conditions, the LED is on; if it flashes or is off, refer to the 
diagnostics table to check amplifier status.

12)

“SET-UP MODE” EQUALIZATION SWITCH

This 10-position rotating switch permits selection of the equalization curve according 
to installation type.
See table for corresponding equalization curve. 

ON

MAINS
FUSE

MAINS
LINK

FULL RANGE MAINS INPUT

BALANCED
INPUT

BALANCED
LINK / OUT

INPUT SENS

READY

MUTE/PROT

SIGNAL

LIMITER

SET-UP
MODE

85-265V

85-125V (T4A 250V)
200-250V (T2A 250V)

BB

dd

TECHNOLOGIES

0dB

+10dB

+4dB

1 = GND
2 = HOT
3 = COLD

"AVIS" 

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR 

POUR PREVENIR TOUT RISQUE DE FEU 

REPLACER UN FUSIBLE 

DE MÊME CARACTERISTIQUES

CET APPAREIL DOIT ÊNTRE RELIÉ A LA TERRE

"CAUTION"

 

TO PREVENT ELECTRICAL SHOCK 

DO NOT REMOVE COVER

TO PREVENT RISK OF FIRE 

REPLACE FUSES WITH

SAME TYPE AND RATINGS 

THIS APPARATUS MUST BE EARTHED

500W MAX

50-60Hz

ACTIVE P.F.C.

SERIAL N.

1

0

2

3

4

5

6

7

8

9

D

igital 

V

ertical 

A

rray

WARNING 

HOT SURFACE 

WARNING 

HOT SURFACE 

WARNING 

HOT SURFACE 

WARNING 

HOT SURFACE 

T4

PU

SH

1

2

4

3

8

9

9

10
11

5

6

7

12

Содержание dB Technologies DVA T4

Страница 1: ...ISTIQUES TECHNIQUES Digital Vertical Array Digital Vertical Array 42 2 0120118 Rev A E B INDUSTRIALE s r l Via Brodolini 8 40056 Crespellano Bo ITALIA Tel 39 051 969870 Fax 39 051 969725 Internet www...

Страница 2: ...R I PA R A B I L I DALL UTENTE AFFIDARE LE RIPARAZIONI APERSONALE QUALIFICATO ATTENZIONE PER RIDURRE ILRISCHIO DI INCENDIO O DI SCOSSA ELETTRICA NON ESPORRE QUESTO APPARECCHIO ALLA PIOGGIA O ALL UMIDI...

Страница 3: ...HOT 3 COLD AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR POUR PREVENIR TOUT RISQUE DE FEU REPLACER UN FUSIBLE DE M ME CARACTERISTIQUES CET APPAREIL DOIT NTRE RELI A LA TERRE CAUTION TO PREVENT ELECTRI...

Страница 4: ...ilation Do not block any of the ventilation openings Install in accordance with the manufacturers instructions The appliance should be situated so that its location or position does not interfere with...

Страница 5: ...iance beyond that is described in the Operating Instructions All other servicing should be referred to qualified service personnel CAUTION CONTROLS AND FUNCTIONS 1 POWER SWITCH This switch permits tur...

Страница 6: ...t input audio signal applied NOISE GATE starts to work when there is no audio signal on input after a few seconds it sets the amplifier section in MUTE state MUTE state is indicated by slow flashing o...

Страница 7: ...dendienst erfordern Wenden Sie sich f r jegliche Reparatur an einen Fachmann Ein technischer Eingriff ist erforderlich wenn Das Ger t besch digt wurde Das Netzkabel oder der Netzstecker besch digt wur...

Страница 8: ...ausgeschaltet ist kann man der Diagnosetabelle Informationen zur Kontrolle des Zustands des Verst rkers entnehmen 12 SET UPMODE EQUALIZATION SWITCH An diesem 10 Positionen Drehknopf wird die Equalizer...

Страница 9: ...t de piscines Nettoyage Pour le nettoyage des parties ext rieures vitez les diluants l alcool l essence ou autres substances volatiles Ventilation Ne jamais placer l appareil dans un endroit qui risqu...

Страница 10: ...d assurer le maximum de fiabilit dans toutes les applications professionnelles Un syst me sophistiqu de gestion de l amplificateur se charge des protections limiteur thermique et contre les courts ci...

Страница 11: ...SE GATE se visualise gr ce aux led pr sents sur le panneau amplificateur durant l allumage du module Fonction activ e tous les led allum s pendant 5 6 secondes Fonction d sactiv e seul le led jaune MU...

Страница 12: ...dBTechnologies L ente certificatoreT V non ha omologato nessun altro accessorio per questo uso Installare sempre le parti in conformit con queste istruzioni di installazione Compilare e archiviare tut...

Страница 13: ...iation and Operation No structural modifications may be made without the manufacturer s consent Use only dBTechnologies original parts Use only dBTechnologies original parts TheT V authorizing body ha...

Страница 14: ...em DRK 10 Flugrahmen Original dB Technologies Teile Hinweis Inbetriebnahme und Betrieb Es d rfen ohne zustimmung des Herstellers keine bauartlichen Ver nderungen vorgenommen werden Versenden Sie aussc...

Страница 15: ...15 CURVED set up 1 set up 1 set up 1 CONFIGURATION FRONT FIELD N 2 OF BOX CURVED from 5 to 15 CONFIGURATION SYSTEM CONFIGURATION FRONT FIELD N 2 OF BOX 9 9 SERVICE USE ONLY DVA T4 PRESET EQUALIZATIONS...

Страница 16: ...io Groundstack 29 30 Phase 1 Phase 2 Phase 4 Phase 3 INCLINAZIONE INCLINATION NEIGUNG INCLINAISON 5 7 5 7 12 5 12 5 1 5 1 5 10 10 5 5 E E S RI S E E S RI S Phase 6 Phase 5 Phase 7 Phase 8 INSTALLAZION...

Страница 17: ...2 5 2 5 GROUND STACKED USE ONLY GROUND STACKED USE ONLY 2 5 2 5 2 5 2 5 2 5 2 5 7 5 7 5 7 5 7 5 5 5 5 5 7 5 7 5 12 5 12 5 15 15 0 1 0 1 5 5 R S SE IE R S SE IE In appoggio Groundstack INSTALLAZIONE I...

Страница 18: ...in appoggio verticale DVA T4 montaggio Ground stacking Supported use DVA T4 Ground stacking assembling DVA T4 DVA S20 Utilizzo in appoggio verticale DVA T4 montaggio Ground stacking Supported use DVA...

Страница 19: ...Per supporto asta Stand adaptor 35 36 Opzione DSA 4 DSA 4 Option In appoggio Floor stack Per supporto asta Stand adaptor Solo con DVA S10 Only with DVA S10 In appoggio Floor stack...

Страница 20: ...38 37 Carello opzione DT 6 Trolley DT 6 option Carello Trolley Flybar Flightcase per 4 DVA T4 opzione DF 4 Flightcase for 4 DVA T4 DF 4 option Opzione DTF 4 DTF 4 Option DTF 4 DT 6 DF 4...

Страница 21: ...ro con staffa e catene Wall bracket and chains fixing 40 Gli accessori per il fissaggio della staffa non sono forniti in dotazione The fixing accessory for wall bracket are not suppling with the kit F...

Страница 22: ...PLY TEMP SENSOR BALANCED LINK OUTPUT INPUT SENS BALANCED INPUT MicroController Unit L N FULL RANGE MAINS INPUT MAINS LINK WOOFER 8 MIDRANGE 6 5 COMPRESSION DRIVER 1 COMPRESSION DRIVER 1 Switching Mode...

Отзывы: