40
Characteristic
AEA Technology E20/20 TDR and
Avionics TDR Specification
Display Plots
Impedance Scales
Zo +10, +25, +50, +100, and 0-200,
500, or 999 Ohms
Range Scales: Feet
Meters
0-10, 20, 50, 100, 200, 500, 1,000,
2,000, 5,000, 10,000, and 20,000ft
0-2, 5, 10, 20, 50, 100, 200, 500,
1,000, 2,000, and 5,000m
Cursors
2 with independent distance and
Impedance, plus delta data
Zoom
Adjustable zoom ranges on active
cursor
Noise Filtering
ON/OFF
Input Protection
Continues Operation
1.0VAC Pk-to-Pk, or 50VDC
High Voltage Warning
Over 1.0VAC Pk-toPk, 50VDC
Protection Limit
250VAC or VDC
Advanced Features
Micro Fault Detection:
Kinks Only –
All Faults –
Locates coax crimps or crushes too
small for easy detection on
impedance trace
Enhances any faults on any cable
type, removes dribble up (DC loop
resistance) for flatter trace
Cable Sampler
Computes VF on sample length
VF Search
User adjust VF to known event or
cable end
Test Lead Null
Removes lead from measurement
Start Distance Off Set
Adjust trace’s start distance to
improve resolution in range scales
Cable Trace Tones (Hz)
900/1100 warble, & 977.5, 850, 577,
and Pocket Toner DC voltages All
steady or pulse selectable
Setup Wizard
Guides user through set ups
Context Sensitive Help
For any action key or menu item
Smart Charger settings
Use NiMH, NICD, Akaline cells, 400-
5000mAhr rated.
Real Time Clock
Date/time stamps saved traces
Cable List
64 programmed cables, user select,
edit and overwrite. ETDR PC Vision
can upload or download revised lists.
Memory
32 Display Traces/ Instrument setups
with trace name and date time stamp